background image

8

805757 v1.05 06.21 Miniboil Install Instructions

Installation

Filter insertion and replacement (Fig 3)

Align the tabs of the cartridge with the filter housing and insert it up 
into the socket.
Turn the cartridge a quarter turn to the right until it locks into position.
Reverse this procedure for removal.

Step E - Connecting the tap

•  Trim excess silicone tubes to ensure a continuous fall back to 

the Command Centre.

•  New hose sets supplied with the unit should be used. Do not 

use old hose sets.

•  Do not loop or allow sagging or kinking of the tubes, to 

prevent water from being trapped inside.

•  When connecting, slide the tube over the pipe at least 15mm. 

Measure and trim the Red silicone tube and connect it to the BOILING 
outlet located on the top of the Command Centre.
Measure and trim the CLEAR silicone tube and connect it to the vent 
outlet located on the top of the Command Centre. 
For Boiling Ambient models, measure and trim the blue LDPE tube and 
connect it to the AMBIENT outlet located on the top of the Command 
Centre (see Fig 4). 
Connect the tap USB connector to the USB lead on the Command 
Centre. It should be fitted together tightly until a "click" is felt. Failure to 
fully insert the connector will prevent tap operation. Once connected, 
fix the cable to the wall, ensuring it is off the floor and away from any 
possible water splashes. 
Turn on water and check for leaks.

Step F - Testing and commissioning 

The appliance is now running in normal operating mode. The Red LED 
will flash until factory set temperature is reached.

Filter flush

When commissioning, it is advisable to flush the filter for several 
minutes to remove any fine filter particles. Use a bucket to collect and 
dispose of the waste water.
To flush the filter, first turn on the water supply and then turn on the 
flush valve (see Fig 6.). Discharge approximately 7.5L of water into the 
bucket. 
Once the filter has been flushed, turn the flush valve off. 
Wait 5 minutes after this point to allow adequate fill time.
The unit is now ready for use. Test water delivery from the tap and 
check for appropriate temperatures. Use cable clips to tidy and secure 
wiring.

ON

OFF

Fig 6. Flush Valve

Open 

position

Closed 

position

Fig 3. Cartridge replacement

Cartridge 
Removal

Cartridge 
Insertion

ROTATE

PULL 

DOWN

1

2

1

2

ROTATE

INSERT

Fig 5. Boiling Only model: 
Connection viewed from the top

Fig 4.Boiling/Ambient models: 
Connection viewed from the top

Summary of Contents for Miniboil BA

Page 1: ...1 805757 v1 05 06 21 Miniboil Install Instructions Installation instructions user manual Zip Miniboil AFFIX PRODUCT LABEL HERE 805757 Models Boiling Ambient Boiling Only...

Page 2: ...of the appliance when full of water Before Commissioning 1 Check the unit has been secured correctly 2 Flush the supply line before connecting 3 Check all plumbing fittings have been tightened 4 Ensur...

Page 3: ...lation requirements 5 Special tools required 6 Installation 6 Step A Installing the tap 6 Step B Installing the filter 7 Step C Installing the Command Centre 7 Step D Connecting the water supply 7 Ste...

Page 4: ...s steam and or boiling water may discharge through a vent outlet at the mouth of the tap If the tap is not installed using the Font pedestal ensure the tap body is located so the tap outlet safely dra...

Page 5: ...site Sufficient space in the cupboard to install the command centre in accordance with these Installation Instructions NOTE Allow clearance of 50 mm around all sides and 200mm above the command centre...

Page 6: ...ture seal against the bench sink top A light smearing of silicon sealant on the underside of the spacer will ensure a watertight fit 4 Pass the hoses through the 35mm hole and carefully locate the Hea...

Page 7: ...essary for efficient operation Adjust cupboard door hinges and attach the supplied silicone door buffers to create a 4 mm air gap between the doors and the cupboard This is the minimum ventilation req...

Page 8: ...ntre It should be fitted together tightly until a click is felt Failure to fully insert the connector will prevent tap operation Once connected fix the cable to the wall ensuring it is off the floor a...

Page 9: ...be dispensed All LEDs Fault Flashing there is a fault in the unit In that case switch off the unit for at least 20 seconds If the fault has not been corrected when the unit is switched on again contac...

Page 10: ...ed as follows 1 Turn off the water supply 2 Use the tap to dispense ambient and hot water until no more water flows to empty the system 3 Disconnect the appliance from the power supply After prolonged...

Page 11: ...ed on Check for loom connection Slow water recovery after use Unit is in Sleep Mode Possible internal fault Touch Hot lever and wait for Red LED to stop flashing Wait for Red LED to stop flashing Cont...

Page 12: ...7 The terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and further patent applications...

Reviews: