Zip Miniboil BA Installation Instructions & User Manual Download Page 9

9

805757 v1.05 06.21 Miniboil Install Instructions

Operation

Note: If the appliance has not been used for several days, allow the tap to 
run ambient water for about one minute.

Tap Operation

Press the RED lever and the SAFETY button to dispense boiling water.
Pull the RED lever up while holding the SAFETY button to dispense boiling water 
continually. The water will flow for about 15 seconds. Then manually return the 
lever to the off position.
Press the BLUE lever to dispense cold (ambient) water. Pull the lever up to 
dispense ambient water continually. The water will flow for about 15 seconds. 
Then manually return the lever to the off position.

Tap Lights

Red LED: Boiling water

•  Steady light: boiling water is ready and can be dispensed.
•  Flashing: the water temperature is below the set value. Boiling water 

cannot be dispensed.

•  Flashing slowly: the unit is in Sleep mode.

Blue LED: Cold (ambient) water (for BA model only)

•  Steady light: ambient-temperature water can be dispensed.

All LEDs: Fault

•  Flashing: there is a fault in the unit. In that case, switch off the unit for 

at least 20 seconds. If the fault has not been corrected when the unit is 
switched on again, contact customer service.

Change Filter light

•  Off: Indicates the water filter is operating within its normal specified 

lifespan.                                                                                                  

•  Flashing slowly: Indicates the water filter is due for replacement, after 12 

months of use or after dispensing 4000 litres, whichever occurs first. To 
replace the filter, refer to Fig 3. After the filter is changed, it should be 
flushed. Refer to Filter flush on previous page.

•  Reset filter counters: After filter is changed, hold down BOTH LEVERS for 

10 seconds. The Filter Change light will turn ON, and after 10 seconds will 
turn OFF. This will reset the filter counters to zero.

Boiling water (BA model):

Press or pull the red lever, 
and cover the Safety button 
at the same time.

Boiling water will be 
dispensed.

Change Filter light

Boiling Only model:

Press or pull either red 
lever, and cover the Safety 
button at the same time.

Boiling water will be 
dispensed.

Cold (ambient) water  
(BA model):

Press or pull the blue lever.

Cold water will be 
dispensed.

Summary of Contents for Miniboil BA

Page 1: ...1 805757 v1 05 06 21 Miniboil Install Instructions Installation instructions user manual Zip Miniboil AFFIX PRODUCT LABEL HERE 805757 Models Boiling Ambient Boiling Only...

Page 2: ...of the appliance when full of water Before Commissioning 1 Check the unit has been secured correctly 2 Flush the supply line before connecting 3 Check all plumbing fittings have been tightened 4 Ensur...

Page 3: ...lation requirements 5 Special tools required 6 Installation 6 Step A Installing the tap 6 Step B Installing the filter 7 Step C Installing the Command Centre 7 Step D Connecting the water supply 7 Ste...

Page 4: ...s steam and or boiling water may discharge through a vent outlet at the mouth of the tap If the tap is not installed using the Font pedestal ensure the tap body is located so the tap outlet safely dra...

Page 5: ...site Sufficient space in the cupboard to install the command centre in accordance with these Installation Instructions NOTE Allow clearance of 50 mm around all sides and 200mm above the command centre...

Page 6: ...ture seal against the bench sink top A light smearing of silicon sealant on the underside of the spacer will ensure a watertight fit 4 Pass the hoses through the 35mm hole and carefully locate the Hea...

Page 7: ...essary for efficient operation Adjust cupboard door hinges and attach the supplied silicone door buffers to create a 4 mm air gap between the doors and the cupboard This is the minimum ventilation req...

Page 8: ...ntre It should be fitted together tightly until a click is felt Failure to fully insert the connector will prevent tap operation Once connected fix the cable to the wall ensuring it is off the floor a...

Page 9: ...be dispensed All LEDs Fault Flashing there is a fault in the unit In that case switch off the unit for at least 20 seconds If the fault has not been corrected when the unit is switched on again contac...

Page 10: ...ed as follows 1 Turn off the water supply 2 Use the tap to dispense ambient and hot water until no more water flows to empty the system 3 Disconnect the appliance from the power supply After prolonged...

Page 11: ...ed on Check for loom connection Slow water recovery after use Unit is in Sleep Mode Possible internal fault Touch Hot lever and wait for Red LED to stop flashing Wait for Red LED to stop flashing Cont...

Page 12: ...7 The terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and further patent applications...

Reviews: