WARNINGS

1.  The Zip HydroTap unit must be earthed. The resistance of the earth connection 

from each exposed metal part must be less than 1 ohm.

2.  All Installation and service work must be completed by trained and suitably 

qualified Tradespeople. Faulty operation due to unqualified persons working on 

this product, or any other Zip product may void warranty coverage.

3.  Plumbing and electrical connections must be made in accordance with local 

regulations and relevant standards. In Australia and New Zealand: Plumbing 

standard AS/NZS 3500 & Electrical Wiring Rules AS/NZS 3000.

4.  This HydroTap product is rated for 230V 50Hz AC operation.
5.  This unit must be installed with adequate clearances of 50mm on all sides, and 

200mm above, to allow for air circulation. Additional means of ventilation is 

critical if the vent kit, as supplied, cannot be fitted.

6.  Flush water supply lines before any plumbing connections are made, to prevent 

sediment from affecting operation.

7.  The Command Centre must not be located near, or cleaned with water jets.
8.  This product is designed for indoor use and must not be installed outdoors or 

exposed to the elements of nature.

9.  For safe operation, the HydroTap is designed to be installed, commissioned and 

used within 48 hours. Should the HydroTap not be required for an extended 

period of time (72 hours or more), do not fill and commission the HydroTap until 

ready for first use.

10. For water taste and quality reasons, following any non-use period of more 

than 72 hours, Zip recommends to perform a system flush. Failure to flush the 

system may affect water quality.

11. Due to the process of continuous improvement, Zip Water reserves the right to 

change details mentioned in this manual, without notice.

WARNINGS

!

Summary of Contents for HydroTap G4

Page 1: ...801525 v3 05 09 20 HT C Com Install Instructions Page 1 of 16 Affix Model Number Label Here 801525 Chilled Commercial Zip HydroTap G4 Installation and Operating Instructions...

Page 2: ...Install Instructions Tap options The Zip HydroTap G4 appliance series offers a range of interchangeable taps to suit the customer s needs These three taps are directly compatible with the G4 Command C...

Page 3: ...uctions STEP 1 Measure and cut all the tap holes before fitting the taps Refer to the Tap installation instruction book 803341 STEP 2 Check for adequate ventilation Section 2 Ventilation 2 1 Details 1...

Page 4: ...ting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing fittings have been tight...

Page 5: ...sing tap mounted on a sink or bench which may be used for commercial applications These units utilise a conventional refrigerant compressor to chill the water which is factory set to 5 9 C These units...

Page 6: ...the power cable is damaged it must be repaired only by a qualified technician To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson The power cable and...

Page 7: ...w for air circulation Additional means of ventilation is critical if the vent kit as supplied cannot be fitted 6 Flush water supply lines before any plumbing connections are made to prevent sediment f...

Page 8: ...ht Kg Tank Material Chilled Only C125 125 no 1x10A 0 175 336 x 476 x 335 20 Stainless C175 175 no 1x10A 0 300 336 x 476 x 335 20 Stainless Major Components and Accessories Parts supplied Description H...

Page 9: ...braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the Command Centres are installed A cold water supply with a minimum working pressure of 150kPa...

Page 10: ...learances are provided It is recommended to install vent duct and louvre panels for under floor and or door vent systems Note Inlet and outlet vents should be separated by a minimum of 100mm to avoid...

Page 11: ...vent kit as supplied is not fitted Additional ventilation is required Options include the HydroTap vent tray kit or auxiliary fan kit Contact your local service centre for availability Vent tray kit...

Page 12: ...gths supplied Note Note the hoses the hoses need to have a need to have a constant downward constant downward gradient to the gradient to the Hydrotap to allow all Hydrotap to allow all water to drain...

Page 13: ...ing further options refer to the User Guide 4 2 Filter Flush 4 1 Select the Language Initial Commissioning screen Language selection screen A new filter cartridge is provided but NOT fitted inside the...

Page 14: ...esh water at installation Dispense 6 litres of chilled water from the chilled outlet equivalent of two complete tankfuls of water 1 Turn the stop cock ON 2 Press Start Stop buttons to start and stop t...

Page 15: ...r OverRun Compressor too Hot Check ventilation Water Supply Failure No water Check water supply is turned ON Cold Sensor Open Internal fault Call Zip Service Cold Sensor Closed Internal fault Call Zip...

Page 16: ...he terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and further patent applications are...

Reviews: