801525 v3.05 09.20 HT C Com Install Instructions

Important Safety Instructions

This manual contains important safety and installation instructions for the Zip HydroTap G4.

Safety

This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision 

or instruction concerning use of the appliance by a person responsible for their safety. Children should be 

supervised to ensure that they do not play with the appliance.

For products sold in Europe, this appliance can be used by children aged from 8 years and above and 

persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use of the appliance in a safe way and understand 

the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be 

made by children without supervision.

Qualifications

If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all 

installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power 

outlet must be in a safe visible position for connection.

Lifting

Take care when lifting the Zip HydroTap unit. Some units may exceed safe lifting limits. If you feel this is 

beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked 

on the packaging. Do not lift the unit by the front cover or any connections at the top rear of the unit. Refer to 

page 7 for the weight of your product. 

Airflow

The ambient temperatures this unit should operate within are 5ºC -  35ºC. Proper air circulation must be 

provided. The system will operate satisfactorily only if the recommended air gaps are provided. If a vent kit is 

supplied it must be fitted. See technical specifications for correct installation to prevent overheating. 

Positioning

It is important to ensure the Command Centre is positioned in an accessible area close to the floor level. The 

unit must have its base mounted in a horizontal position with all inlets and outlets facing up. The Tap must be 

located above the Command Centre.

!

Summary of Contents for HydroTap G4

Page 1: ...801525 v3 05 09 20 HT C Com Install Instructions Page 1 of 16 Affix Model Number Label Here 801525 Chilled Commercial Zip HydroTap G4 Installation and Operating Instructions...

Page 2: ...Install Instructions Tap options The Zip HydroTap G4 appliance series offers a range of interchangeable taps to suit the customer s needs These three taps are directly compatible with the G4 Command C...

Page 3: ...uctions STEP 1 Measure and cut all the tap holes before fitting the taps Refer to the Tap installation instruction book 803341 STEP 2 Check for adequate ventilation Section 2 Ventilation 2 1 Details 1...

Page 4: ...ting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing fittings have been tight...

Page 5: ...sing tap mounted on a sink or bench which may be used for commercial applications These units utilise a conventional refrigerant compressor to chill the water which is factory set to 5 9 C These units...

Page 6: ...the power cable is damaged it must be repaired only by a qualified technician To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson The power cable and...

Page 7: ...w for air circulation Additional means of ventilation is critical if the vent kit as supplied cannot be fitted 6 Flush water supply lines before any plumbing connections are made to prevent sediment f...

Page 8: ...ht Kg Tank Material Chilled Only C125 125 no 1x10A 0 175 336 x 476 x 335 20 Stainless C175 175 no 1x10A 0 300 336 x 476 x 335 20 Stainless Major Components and Accessories Parts supplied Description H...

Page 9: ...braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the Command Centres are installed A cold water supply with a minimum working pressure of 150kPa...

Page 10: ...learances are provided It is recommended to install vent duct and louvre panels for under floor and or door vent systems Note Inlet and outlet vents should be separated by a minimum of 100mm to avoid...

Page 11: ...vent kit as supplied is not fitted Additional ventilation is required Options include the HydroTap vent tray kit or auxiliary fan kit Contact your local service centre for availability Vent tray kit...

Page 12: ...gths supplied Note Note the hoses the hoses need to have a need to have a constant downward constant downward gradient to the gradient to the Hydrotap to allow all Hydrotap to allow all water to drain...

Page 13: ...ing further options refer to the User Guide 4 2 Filter Flush 4 1 Select the Language Initial Commissioning screen Language selection screen A new filter cartridge is provided but NOT fitted inside the...

Page 14: ...esh water at installation Dispense 6 litres of chilled water from the chilled outlet equivalent of two complete tankfuls of water 1 Turn the stop cock ON 2 Press Start Stop buttons to start and stop t...

Page 15: ...r OverRun Compressor too Hot Check ventilation Water Supply Failure No water Check water supply is turned ON Cold Sensor Open Internal fault Call Zip Service Cold Sensor Closed Internal fault Call Zip...

Page 16: ...he terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and further patent applications are...

Reviews: