802253UK - Boiling chilled residential installation instructions - Aug 2015 - V2.02
Note 5
Before you install a booster, determine whether an external water filter / softener is required. If an
external water filter / softener is required, the external bypass valve must be set correctly, see page 26.
Booster specifications
Rating
Unit
Nominal power rating
2.2
kW
Nominal current
10
A
Electricity supply 50Hz AC
230
V
Electrical flex, white - 0.6m nom. length
13
A
Fixed flow rate
1.2
L/min
Section 3
Booster system
Mount base
horizontally
3.1
Product description
The booster system is a compact electronically
controlled auxiliary water heater. It is intended to
provide pre-heating of water before it enters the Zip
HydroTap
®
G4 boiling tank. The booster is used to
present approx. 55°C hot water for sanitary use to a
secondary outlet with additional “Vented Mixer” kit.
Note 1
Water connection
blue cap - water in
red cap - water out.
The braided hoses cannot be
lengthened.
Note 2
The electrical cable
length is 0.6m.
Note 3
Position the booster
within reach of the fixed hose
lengths, keeping the booster
as close as possible to the
Command-Centre
TM
inlet /
outlet connections.
Note 4
Ensure the booster
is mounted in an
upright position (as shown)
with a horizontal base.