802253UK - Boiling chilled residential installation instructions - Aug 2015 - V2.02
Page 11 of 36
Special tools required
In addition to normal tools, the following will be required.
For the HydroTap
®
G4 and mixer taps.
•
35mm diameter sheet metal hole punch for sink tops (not supplied).
•
35mm diameter hole saw for worktops (not supplied).
•
Nut runner tube spanner (supplied) for fixing the tap assembly.
For the All-in-One tap.
•
50mm diameter sheet metal hole punch for sink tops (not supplied).
•
50mm diameter hole saw for worktops (not supplied).
•
Nut runner tube spanner (supplied) for fixing tap assembly.
When installing a font, the following will be required
•
Classic and Elite, 108mm diameter sheet metal or hole saw to suit surface being cut.
•
Arc / Cube and All-in-One, 140mm diameter sheet metal or hole saw to suit surface being cut.
Hole positioning
Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot.
Alternatively, the tap could be mounted away from the sink using a Zip Font, available as an accessory
(see Major components and accessories, page 8).
Tap positioning
Section 1
Tap installation
Tap
Recommended dispensing
distance (mm)
Elite
116
HydroTap
®
Classic
116
HydroTap
®
Arc/Cube
171 (174 extended)
All-in-One
211
Mixer - Arc
231
Mixer - Classic
270
Mixer - Cube
310
HydroTap
®
G4 Classic
116
Note
All-in-One and mixer taps have spouts that swivel.
All images are for illustrative purposes, to aid understanding of the system
configuration, and are not prescriptive of tap positioning.
•
Ensure that the taps are mounted to minimise the risk of scalding by
accidentally dispensing boiling water while using the mixer.
•
Ensure that the taps are mounted in a position that allows the water to
safely drain to waste throughout the complete positional range.