3.
LCD Screen operation - Section G
t
ions
1.
Press the [MENU] button for main
menu.
2.
Press the [Temperature] button.
3.
To adjust the temperature, press
the relevant temperature button and
then use the up and down arrows.
4.
Press [HOME] to return to the Home
screen.
Zip HydroTaps are designed to operate within 1ºC to 2ºC of set point for
boiling water and between 6ºC to 10ºC (5ºC to 10ºC for CS175) for chilled
drinking water. All boiling water units are self calibrating to 98ºC, which is the
recommended setting. Adjustments to the 98ºC setting are not recommended
however, under certain circumstances adjustments may be made between
68º - 100ºC. It should be noted that a 20% energy saving in standby power
can be achieved when the 98ºC setting is selected over the 100ºC setting.
Furthermore, the 100ºC setting is not recommended as the delivery rate of
water may be affected.
Set Temperature
1.
Select individually the hour, minutes
and day and adjust using the up
and down arrows.
2.
Select individually the date, month
and year and adjust using the up
and down arrows.
3.
Press [HOME] to return to the
Home screen.
1. Press the [MENU] button for main
menu.
2. Press the [Setting] button.
3. Press the [Date/Time] button.
4. Select either 12 hour or 24 hour
mode. The selected mode will be
displayed in a dark grey colour with
a tick box on the right.
5. Press [NEXT] to set the time and
date
G4 HydroTap Set
Date/Time Screen
Set Date / Time