802265 - Sparkling HT- BCS Compact Commercial - Installation Instructions - 09.16 - v3.01
Commissioning
6.5
-
Safety Sensor Calibration
(Classic and All-In-One models)
Disable
Booster
10:30 Wed 14, Nov 2013
BC Sparkling
Zip
1. Press the [MENU] button for main menu.
2. Press the [Install] button.
3. Press the [Booster] button.
4. In the next screen, press button to enable the
Booster.
5. Water must be run through the Booster for a min of 30
seconds, before the heater will activate.
6. Dispense boiling water for 30secs and check the Boost-
er outlet hose is warm when the boiling water tank is
replenishing.
Enable
HOME
To enabled when a Booster unit is installed.
A
A
Pull both levers
forward
Safety
sensor
1.
With the unit in Normal operating mode and with
the safety enabled
2.
Turn the power OFF
3.
Pull both tap levers to the forward position
4.
Turn ON the power
5.
The unit will calibrate the safety switch
6.
Return the levers to the neutral position.
7.
To check the calibration, dispense Boiling water,
in normal light conditions with the safety enabled.
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the
time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration.
This can be achieved by closing any nearby curtains, blinds, or by shielding the HydroTap with a dark cloth.
NOTE:
Depending on your location you may need to re-set the internal clock. See section G of the user
guide to check and if necessary, reset the Date and Time for your time zone.
6.6
-
Date and Time check