Page 20 of 24
Hydro Tap Installation and Operating Instructions - 89026UK - June 2009
Boiling Water Isolation
(Model 437677UK)
The HydroTap is equipped with an additional safety mode that allows
protection against accidental operation by Infirmed or disabled persons.
1. On the LCD scroll through the menu to Hot Isolation.
2. Press adjust
>
to activate.
3. Now go to the Tap Head assembly and press the Safety Lock (3) three
times rapidly, the LED’s will scroll from left to right (3) three times. This
operation confirms the activation.
4. This isolates the boiling tap only. The LCD shows isolation mode is active.
5. To de-activate, press the Safety Lock (3) three times rapidly, the LED’s
will scroll from right to left (3) three times. This operation confirms
de-activation.
6. The LCD will show Normal Operation.
7. If de-activation mode is required, de-activate by scrolling through the
menu and selecting de-activate when Hot isolation Mode is displayed on
the screen.
Set the Hot & Cold water dispensing times
The ability to change the maximum dispensing time for both the Hot and Cold
water has been introduced. The default settings for the maximum dispensing
times is 15 secs. The ability to change both the Hot and Cold dispensing times
between 5 and 15 secs, in increments of 1 sec, is accessible through the
Menu screen on the LCD.
Scroll through the Menu until the Dispense Hot screed is displayed, then use
the adjust buttons to set the required dispensing time for the Hot water.
Follow the same procedure to access the Dispense Cold or Dispense Amb (on
boiling ambient models) screens.