19
INSTALLATION INSTRUCTIONS & USER MANUAL
T210013 V1.00 FEB 2018 -ZIP HYDROCHILL 20
TECHNICAL SUPPORT
TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
FILTER
If the HydroChill is switched off for a long period of time
(e.g. more than a weekend), run water through the chilled
water outlet for at least 5 minutes before consumption.
Caution
Water will drip as the cartridge is removed.
Do not tilt the cartridge as water may spill from it if
tilted.
• Isolate the water supply.
• Unpack replacement cartridge and remove sanitary
cap, write today’s date where shown on the label.
Avoid touching the filter o-rings and filter opening as
this may cause bacterial contamination of the cartridge.
• Align the front cartridge label to the left (as shown in
the “insert filter” diagram adjacent), and push the new
cartridge up into the filter head.
• Turn the cartridge a quarter turn anticlockwise until
it comes to a complete stop and locks, with the front
label facing forward.
• Turn on the water supply.
• Flush the filter by dispensing chilled or ambient water
for 5 mins.
• When completed, clean up and dispose of old cartridge
and packaging.
Remove filter
Insert filter
Rotate
Insert
!
WARNING
!
Filter removal, replacement & flush
Rotate
Pull