background image

12

INSTALLATION INSTRUCTIONS & USER MANUAL 

T210013 V1.00 FEB 2018 -ZIP HYDROCHILL 20

TECHNICAL SUPPORT

 TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK   

WWW.ZIPWATER.CO.UK

INSTALLATION

Unpacking

•  Remove the plastic straps.

•  Lift the internal cardboard box up and out 

of the cage.  

•  Once you have unpacked the HydroChill, 

check to ensure that it is not damaged. 

•  If the HydroChill has been shipped 

horizontally or at an angle, it will be 

necessary to wait at least 8 hours before 

setting it up, in order to allow the cooling 

circuit to reset itself.

•  Ensure that the unit is installed and 

connected to the mains water and electricity supplies by a qualified 

technician, in compliance with the manufacturer’s instructions and the local 

safety regulations.

Note 

there are no user serviceable part inside the HydroChill. 

Summary of Contents for HYDROCHILL HC20 Series

Page 1: ...T210013 V1 00 FEB 2018 ZIP HYDROCHILL 20 TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP HYDROCHILL INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER HC...

Page 2: ...ing the HydroChill 5 Approvals 5 Product description 6 Technical features 7 Explanation of product codes 7 Front of HydroChill 7 Rear of HydroChill 8 Rating plate 9 Dimensions 10 Technical data 11 Ins...

Page 3: ...Take care not to damage the cooling fluid circuit it is filled with R290 gas which is highly flammable It is essential to ensure that the tubes of the refrigerant circuit are not damaged Ensure that...

Page 4: ...for their safety Children should be supervised to ensure that they do not play with the appliance The appliance is only to be installed in locations where it can be overseen by trained personnel This...

Page 5: ...spense water of the highest quality In order to get the most out of your HydroChill please read the instructions in this manual and retain the manual for future reference APPROVALS This HydroChill is...

Page 6: ...strong materials and a front plexi glass panel with elegant lighting Highly insulated ice bank Cooling serpentine coil made with AISI grade 316 stainless steel for wholesome water 2 supply options chi...

Page 7: ...Drip tray with ice bank drain pipe Antishock feet 4 5 1 2 5 3 4 Explanation of HydroChill range product code HC HydroChill Range Product group 10 range 20 range 50 range C Chilled only Chilled sparkli...

Page 8: ...IL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK TECHNICAL FEATURES 6 7 4 5 8 1 2 3 Rear of HydroChill Ice bank inlet pipe fitting 8 mm Wholesome cat 1 water inlet pipe fitting 8 mm 1 2 3 4 5 6 7 8 E...

Page 9: ...ss N Made in Italy Serial no PRODUCT 230V 50 Hz KW A RoHS COMPLIANT 2011 65 EU wholesome water only GAS g Product identifying part number Supply voltage Unique product serial number Refrigerant gas ty...

Page 10: ...UAL T210013 V1 00 FEB 2018 ZIP HYDROCHILL 20 TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK TECHNICAL FEATURES DIMENSIONS 566 502 321 565 360 618 542 373 606...

Page 11: ...nk capacity l 14 18 Ice bank kg 5 8 Pump Professional membrane carbonation pump Professional rotary carbonation pump Condensation Forced ventilation Adjustable thermostat Yes Refrigerant gas R290 Elec...

Page 12: ...he HydroChill check to ensure that it is not damaged If the HydroChill has been shipped horizontally or at an angle it will be necessary to wait at least 8 hours before setting it up in order to allow...

Page 13: ...equate ventilation Sanitise the HydroChill before first use see page 24 Tighten the tap knobs BT models and position the drip tray 4 Filling the ice bank Fill with wholesome cat 1 water via the rear f...

Page 14: ...mm to 1 2 coupler 1 2 BSP 1 4 push fit Connection to the mains water supply WARNING also see precautions pages 3 4 To connect the HydroChill to the mains water supply always use a new set of connector...

Page 15: ...lation valve not supplied Water block 15mm to 1 2 coupler 1 2 BSP 1 4 push fit Filter head Filter supplied Line counter 1 4 pipe 8mm pipe To HydroChill 8mm 1 4 coupler Connect 8mm incoming water tube...

Page 16: ...ing the I position on the power switch 2 The ice bank pump compressor and fan are now activated Dispense sparkling water 4 in order to release any air in the circuit and to allow the pump to fill the...

Page 17: ...water and electricity supplies install the CO2 cylinder Attach the regulator CO2 pipe to the cylinder valve Insert the CO2 inlet tube from the cylinder into the fitting 1 To be sure to remove any air...

Page 18: ...e cylinders must be handled with care It is essential to avoid Clashes with other cylinders or surfaces dropping the cylinders or subjecting them to mechanical stress All of the above may compromise t...

Page 19: ...tridge and remove sanitary cap write today s date where shown on the label Avoid touching the filter o rings and filter opening as this may cause bacterial contamination of the cartridge Align the fro...

Page 20: ...o work on UV products Sterilizing UV filter Alongside the external filter it is also possible to fit a UV C 254 nm sterilizing filter on the dispensing point The UV C light emitted by the special 4W m...

Page 21: ...ispensing operation IT models Filtered sparkling water P1 1 2 1 2 Filtered sparkling water Filtered chilled water Pull forward the tap handle to dispense Push it back to stop L1 L2 Blue LED stand by F...

Page 22: ...lumetric dispensing functionality you can customise the pre set quantities dispensed by each of the 4 buttons Normally the upper buttons are used for the dispensing of small quantities with the lower...

Page 23: ...as alarm This alarm is triggered when the CO2 pressure switch sends the no gas signal In this case the associated blue led l 1 Starts to flash slowly and all of the dispensers continue to work as norm...

Page 24: ...t cloth and a dedicated stainless steel cleaner To remove lime scale use a proprietary cleaning agent citric acid or similar DO NOT USE alcohol or solvent based products or excessively acidic solvents...

Page 25: ...e of this product correctly Please contact Zip Customer Service for advice on 0345 6 005 005 End of life disposal Packaging materials The packaging materials are 100 recyclable Please follow the local...

Page 26: ...or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from...

Page 27: ...27 INSTALLATION INSTRUCTIONS USER MANUAL T210013 V1 00 FEB 2018 ZIP HYDROCHILL 20 TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK NOTES...

Page 28: ...0013 V1 00 FEB 2018 ZIP HYDROCHILL 20 TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005...