Zip AP3/05 Installation, Maintenance And User Instructions Download Page 3

Specification

Product:

Zip Aquapoint III

Type:

Direct unvented multipoint 

Capacity:

10 litre, 15 litre

Loading:

2.0kW 

Thermostat:

Adjustable 7ºC to 75ºC 

Thermal cut-out:

Manually re-settable set to 85+/-3ºC

Water vessel:

Glass enamelled steel tested to 12 bar. Maximum working
pressure 6 bar

Safety Features:

Expansion relief valve set to 6 bar (supplied)

Manually re-settable over temperature safety cut-out
Provision to fit Pressure and Temperature relief valve 
(available as an optional accessory)
Sacrificial anode to provide anti-corrosion protection for the
vessel and element.

Approvals:

Zip Aquapoint III complies with LVD and EMC directives and 
is CE endorsed.

Zip Aquapoint III has been examåined, tested and found,
when correctly fitted, to comply with the requirements
of the United Kingdom Water Regulations/Byelaws 
(Scotland). The product, therefore, is listed under the
WRAS (Water Regulations Advisory Scheme) Water
Fitting and Materials Directory.

Models:

Underbasin

Overbasin

5 litre

AP3/05

AP3/05/OB

10 litre

AP3/10

AP3/10/OB

15 litre

AP3/15

AP3/15/OB

Performance:

Model

Heat up time

Re-heat time

Heat Loss

(15° to 65ºC)

(70% vol.)

(kW/24 hrs)

AP3/05 (OB)

11 mins

7 mins

0.25

AP3/10 (OB)

18 mins

12 mins

0.33

AP3/15 (OB)

32 mins

18 mins

0.44

4                                                                

AP3/05, AP3/10, AP3/15 Installation Instructions  

New Aquapoint lll qxd:New Aquapoint lll qxd  5/11/08  15:51  Page 3

Summary of Contents for AP3/05

Page 1: ...The terms Zip and Aquapoint are registered trademarks Zip products described in the brochure are manufuctured under one or more of the following patents AU675601 AU637412 AU635979 GBO422305 GB2065848...

Page 2: ...tion 12 Fault Finding 13 Warranty 14 Installation must only be undertaken by a competent person familiar with unvented electric water heaters The Zip Aquapoint must be installed in accordance with the...

Page 3: ...nt Approvals Zip Aquapoint III complies with LVD and EMC directives and is CE endorsed Zip Aquapoint III has been exam ined tested and found when correctly fitted to comply with the requirements of th...

Page 4: ...602 4533 The Zip Aquapoint is an unvented water heater designed for connection directly to the incoming mains water supply and can serve one or more outlets using conventional taps Care should be take...

Page 5: ...nstallation If in doubt or in need of further guidance please call Zip Customer Service on 0845 602 4533 2 Zip Aquapoint unvented water heaters must be installed by a competent installer familiar with...

Page 6: ...with a maximum resistance to flow equivalent to 9 metres of straight pipe 9 An isolating valve must be fitted to the cold water supply 10 Valves and fittings must be of a type required by Water Supply...

Page 7: ...l shown Diagram 1 Inlet pressure less than 4 bar and expanded hot water can be accommodated in the pipe work Diagram 2 Inlet pressure less than 4 bar but expanded hot water cannot be accommodated in t...

Page 8: ...d water supply pipe work as shown in diagrams 1 to 3 7 Flush all pipe work thoroughly before making the final connections to the valves accessories and cold feed to the heater to ensure that any debri...

Page 9: ...to ensure free water flow through the discharge pipe by turning the knob to the left and holding in the open position 9 Set the temperature control knob to the desired position The E position with a...

Page 10: ...space or any other concealed location If there is any sign of leaks or seepage the heater should be isolated from the water supply and switched off from the electrical supply until a competent person...

Page 11: ...unscrewing the element assembly and removing it If the anode is badly corroded it should be replaced after removing it by grasping with long tongs or other suitable tool through the flange opening wh...

Page 12: ...aulty element Thermostat failure Solution Reset If the cut out operates again isolate the unit and contact the installer NB Isolate the electrical supply before removing the electrical cover panel and...

Page 13: ...and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance...