802265 v3.05 09.20 HT BCS Compact Commercial Instructions
Page 27 of 32
1. Press the [MENU] button for main menu.
2. Press the [Install] button.
3. Press the [Booster] button.
4. In the next screen, press button to enable the
Booster.
5. Water must be run through the Booster for a min of
30 seconds, before the heater will activate.
6. Dispense boiling water for 30secs and check the
Booster outlet hose is warm when the boiling water
tank is replenishing.
To enable Booster unit (when installed):
A
Commissioning
6.5
-
Safety Sensor Calibration
(Classic and All-In-One models)
Pull both levers
forward
Safety
sensor
1. With the unit in Normal operating mode and with the safety
enabled
2. Turn the power OFF
3. Pull both tap levers to the forward position
4. Turn ON the power
5. The unit will calibrate the safety switch
6. Return the levers to the neutral position.
7. To check the calibration, dispense Boiling water, in normal light
conditions with the safety enabled.
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the
time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration.
This can be achieved by closing any nearby curtains, blinds, or by shielding the HydroTap with a dark cloth.
Disable
Booster
10:30 Wed 14, Nov 2013
BC Sparkling
Enable
HOME
A