5.4
Install carbonation valve
5.3
John Guest
fittings
(Insertion and removal)
Be careful when cutting the poly tube so that there are
no rough edges and that the tube is not distorted.
1. Use a sharp knife to ensure the tube has a clean,
straight edge. Do not cut at an angle.
2. Remove any swarf or unwanted material.
3. Push the tube into the John Guest fitting making
sure all connections to the John Guest fittings are
pushed in past the “O”ring to full depth, at least
15-16 mm.
4. Check for a good joint by pulling back on the tube.
If the tube comes out of the fitting, repeat the
above step.
5. To remove the tube, press the collet into the fitting
and at the same time pull back on the tube.
1. Fit the carbonation valve to the white tube, as close
as possible to the Y-connector from the tap.
2. Use the white tube to connect the carbonation valve
to the sparkling outlet connection on top of the Com-
mand Centre.
3.
The carbonation valve has an adjustable flow rate.
The optimum setting for the valve is between 1.2 -
1.6 litres per minute. Using a 6mm Allen key or a
large flat blade screw driver, you can adjust the flow
on the valve. See Section 7.7 for carbonation valve
flow rate adjustment.
Warning
- Take care NOT to use excessive
force during adjustment of the valve.
!
Sparkling Water Flow