9.1  Status table

NOTICE:

No signal is on while energizing the coil and until position is stabilized.

10. Sensors

10.1  Sensing the intermediate position

The intermediate position, also referred to as "workpiece gripped," can be programmed as needed. For this pur-

pose, a signal (+24 V) must be applied to input 7 (teach/adjust) for a maximum of 3 seconds. 

In this process, feedback is provided via output 4 (teached position).

The status is visualized on the gripper via the LED display.

10.2  Sensing the end positions

The gripper's end position sensing is preset at the factory. If necessary, end positions can be reset by means of 

an automatic traversing routine. For this purpose, a signal (+24 V) must be applied to input 7 (teach/adjust) for at 

least 10 seconds. 

After 3 seconds, the traversing routine begins and is completed after approx. 20 gripping cycles. If the signal 

(+24 V) is interrupted before the end of the traversing routine, the new end positions are not stored in the internal 

control system.

 End position feedback takes place by means of outputs 2 (closed) and 5 (opened).

The statuses are visualized on the gripper by means of the LED display.

10.3  LED display

Status

Outputs

LED display flashes

opened

teached 

position

closed

opened 



teached 

position



closed 



Programmed gripper position is not 

recognized

I

0

I

I

0

I

Defective position sensor

I

I

I

I

I

I

No coil current

I

I

I

I

I

I

Temperature outside of permitted 

range

I

I

0

I

I

0

Voltage outside of permitted range

0

I

I

0

I

I

Summary of Contents for GEP9000 Series

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS GEP9000 series 2 jaw parallel grippers DDOC00190 THE KNOW HOW FACTORY www zimmer group com...

Page 2: ...190 c EN 2020 02 03 Zimmer GmbH Im Salmenkopf 5 77866 Rheinau Germany 49 7844 9138 0 49 7844 9138 80 www zimmer group com INSTALLATION AND OPERATING INSTRUCTIONS 2 jaw parallel gripper electric GEP900...

Page 3: ...ion 7 7 1 Safety notes 7 7 2 General installation information 7 7 3 Installing the gripper 7 7 4 Installing the gripper fingers 8 7 5 Installing accessories 8 8 Commissioning 9 8 1 Control 9 8 2 Flow...

Page 4: ...intained The grippers are not used for their intended purpose The local regulations legislation decrees guidelines such as the EC Machinery Directive accident prevention regulations and the assembly a...

Page 5: ...ding parts The gripper is not suitable for clamping workpieces during a machining process Direct contact with perishable goods food is not permitted 4 Personnel qualification Installation commissionin...

Page 6: ...cing the stroke NC is suitable for outside gripping and NO is suitable for inside gripping Fig 1 GEP9000 gripper Fig 2 Cutaway view of the GEP9000 gripper 6 1 Technical data INFORMATION For technical...

Page 7: ...General installation information The gripper must be installed on a mounting surface in accordance with the specifications for flatness Length 100 mm permitted flatness imperfection 0 02 mm Length 100...

Page 8: ...TICE Before installing the gripper fingers make sure they are of a suitable length for the selected gripper variant For more information refer to our website Zimmer Customer Service is available to pr...

Page 9: ...wer consumption during the movement of the gripper jaws is 5 A At resting position the power consumption of the gripper is 0 02A 8 2 Flow diagram NC Version 8 3 Flow diagram NO Version PIN Color Funct...

Page 10: ...y cable for defects Check the given current and voltage Send in the gripper for inspection Programmed gripper position is not recognized LED display flashes Workpiece tolerance outside of sensing rang...

Page 11: ...tion sensing is preset at the factory If necessary end positions can be reset by means of an automatic traversing routine For this purpose a signal 24 V must be applied to input 7 teach adjust for at...

Page 12: ...NSTRUCTIONS 2 jaw parallel gripper electric GEP9000 series 10 4 Status table NOTICE There is no signal while the coil is being energized and up until the position is stabilized Status Outputs LED disp...

Page 13: ...grippers Information on the corresponding optional accessories included in the scope of delivery can be found at www zimmer group com 13 Transportation storage preservation The transport and storage o...

Page 14: ...quirements No 1 1 2 No 1 1 3 No 1 1 5 No 1 3 1 No 1 3 2 No 1 3 4 No 1 3 7 No 1 5 1 No 1 5 3 No 1 5 4 No 1 6 4 No 1 7 1 No 1 7 3 We also declare that the specific technical documents were produced in a...

Page 15: ...ignation GEP9 series conform to the requirements of the Electromagnetic Compatibility Directive 2014 30 EU in its design and the version we put on the market The following harmonized standards have be...

Page 16: ...190 c EN 2020 02 03 Zimmer GmbH Im Salmenkopf 5 77866 Rheinau Germany 49 7844 9138 0 49 7844 9138 80 www zimmer group com INSTALLATION AND OPERATING INSTRUCTIONS 2 jaw parallel gripper electric GEP900...

Reviews: