INSTALLATION AND OPERATING INSTRUCTIONS:
Collision protection, pneumatic, CSR series
7
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
EN / 2020-09-15
DDOC00267 / b
8 Installation
8.1 General installation information
WARNING
Risk of injury in case of unexpected movement of the machine or system into which the product is to be installed.
►
Switch off the power supply to the machine before all work.
►
Secure the machine against being switched on unintentionally.
►
Check the machine for any residual energy.
CAUTION
Risk of injury in the event of unexpected movement of the product when the power supply is connected.
►
Switch off the power supply to the product before all work.
►
Secure the power supply against being switched on unintentionally.
►
Check the power supply for any residual energy.
Non-compliance may result in severe injuries!
Spring-loaded components can jump out when installing or uninstalling the device.
Ö
Risk of injury
NOTICE
Switch off the power supply before any assembly, installation or maintenance work.
The product must be installed on a suitable mounting surface in accordance with the flatness specifications.
Ö
Permissible flatness imperfection: 0.03
• Mounting screws are included in the scope of delivery.
•
Strength class of the mounting screws ≥ 8.8 (DIN EN ISO 4762)
• Observe the tightening torque of the mounting screws.
Ö
Zimmer GmbH recommends verifying the permitted load-carrying capacity of the required screw connections in
accordance with VDI 2230.
• The exact installation positions can be found on the technical data sheet on our website.