SP226 

2.2.3

 

Technical data 

Rated voltage 

AC 220V (optional: AC110V) 

Externality size 

450mm*310mm*150mm 

Max. own consumption 

3W 

Range of temperature measuring 

NTC: 0~99

; PT1000: 0~199

 

Accuracy of temperature measuring 

±

1

 

Power of pumps (solar collector pump P1 

and circulation pump P2) 

600W 

Power of auxiliary heating 

3000W

optional: 

6000W

 

System working pressure 

8 bar 

Safety valve response pressure 

6 bar 

Ambient temperature 

0~50

 

Input signals 

T1~T3  (top  part  of  water  tank;  bottom  part  of  water 

tank; solar collector) 

Output signals 

3  (auxiliary  heating;  solar  collector  pump;  solar 

circulation pump) 

 

2.3

 

Double-pipeline solar station: SP226 

2.3.1

 

Components 

 

 

Filling und flushing connecting 

Operation screen   

Pump speed regulation 

WILO pump 

Expansion vessel connector 

Manometer 

Air vent valve 

Security valve 

Mounting point 

10 

Forward flow connector 

11 

Return flow connector 

 

 

 

Summary of Contents for SP226

Page 1: ......

Page 2: ...operation is no longer possible please immediately take the device out of operation Without lightning rod please don t use this device during a thunderstorm 1 3 Liability waiver Improper installation...

Page 3: ...or in bottom part of storage tank T3 Temperature sensor in top part of storage tank P1 Solar collector pump P2 Solar circulation pump Danger If there is only one temperature sensor in water storage ta...

Page 4: ...Pump speed regulation 4 WILO pump 5 Input connector 6 Security valve 7 Expansion vessel connector 8 Output connector 9 Mounting point 2 2 2 Installation description SP116 should be installed in retur...

Page 5: ...System working pressure 8 bar Safety valve response pressure 6 bar Ambient temperature 0 50 Input signals T1 T3 top part of water tank bottom part of water tank solar collector Output signals 3 auxili...

Page 6: ...size 450mm 310mm 150mm Max own consumption 3W Range of temperature measuring NTC10K 0 99 PT1000 0 199 Accuracy of temperature measuring 1 Power of pumps solar collector pump P1 and circulation pump P...

Page 7: ...on Setting three time periods Tank temperature As turning on off temperature value for auxiliary heating Solar system indication For SP116 SP226 only 1 system available Frost protection signal Overhea...

Page 8: ...e Press Confirm button to save the setting press Cancel button to cancel the setting 3 2 Temperature difference circulation function The solar control program works on the principle of temperature dif...

Page 9: ...time period Perform like above steps the other two time periods can be set Note If you want to shut off one of the three time periods you can set a same value for both start time and end time e g you...

Page 10: ...ating Press Choose Function button until displays on the screen Press Confirm button to save the setting and forbid auxiliary heating Press Choose Function button until displays on the screen Press Ca...

Page 11: ...the screen Press button to adjust the maximum collector temperature Default value 115 adjustable range 100 130 Press Confirm button to confirm the setting press Cancel button to quit this function 3 1...

Page 12: ...except time setting can be reset to the factory settings Press Choose Function button until displays on the screen Press Confirm button all of parameters will be reset to factory settings 3 15 Manual...

Page 13: ...ar system Check the pipeline and exhaust the air 6 Pump works but system doesn t have temperature difference meanwhile auxiliary heating function starts up Frost protection function is activated signa...

Reviews: