background image

User

s Manual 

SP226 

 

1

 

General information 

1.1

 

About this manual 

This  manual  describes  the  installation,  function  and  operation  of  an  integrated  solar  pumping  station,  which  is 

suitable  for  split  pressurized  solar  heating  system.  Before  installing  and  operating  the  device,  please  read  the 

following information carefully. 

 

1.2

 

Safety regulations 

 

Installation, commissioning and maintenance of the device may only be performed by professional personal. 

 

All  operations that require  opening the  device  are  only to  be conducted  cleared  from the power  supply.  All 

safety regulations for working on the power supply are valid. 

 

The  device  must  not  be  installed  in  rooms  where  easily  inflammable  material  (e.g.  gas  or  oil)  mixtures  are 

present or may occur. 

 

Before  connecting  the  pumping  station,  make  sure  that  the  energy  supply  matches  the  specifications  of  the 

device. Protect the solar pumping station against overloading and short-circuiting. 

 

All devices connected to the pumping station must conform to the technical specifications of the device. 

 

As soon  as  it becomes evident that safe  operation is  no longer possible, please immediately take the  device 

out of operation.   

 

Without lightning rod, please don

t use this device during a thunderstorm. 

 

1.3

 

Liability waiver 

 

Improper  installation  or  operation  can  cause  damages  to  material  and  persons.  The  manufacturer  cannot 

monitor  the  compliance  with  these  instructions  or  the  circumstances  and  methods  used  for  installation, 

operation, utilization and maintenance of this controller. Damage by mishandling or improper installation on 

costumer site is immediately leading to warranty exclusion. 

 

As faults can never be excluded, we don

t offer a guarantee for the completeness of the drawings and texts of 

this manual, they only represent some examples. They can only be used on own risk. No liability is assumed 

for incorrect, incomplete or false information and the resulting damages. 

 

The  manufacturer  preserves  the  right  to  put  changes  to  product,  technical  date  or  installation  and  operation 

instructions without prior notice. 

 

1.4

 

Symbols used 

Danger

: Failure to observe these instructions can lead to injury of persons or safety risks. 

 

Attention

: Failure to observe these instructions can result in damage to the product or environment. 

 

Note

: Useful information and instructions. 

 

ì

      Operation steps

: Indication of operation steps. 

 

Summary of Contents for SP226

Page 1: ......

Page 2: ...operation is no longer possible please immediately take the device out of operation Without lightning rod please don t use this device during a thunderstorm 1 3 Liability waiver Improper installation...

Page 3: ...or in bottom part of storage tank T3 Temperature sensor in top part of storage tank P1 Solar collector pump P2 Solar circulation pump Danger If there is only one temperature sensor in water storage ta...

Page 4: ...Pump speed regulation 4 WILO pump 5 Input connector 6 Security valve 7 Expansion vessel connector 8 Output connector 9 Mounting point 2 2 2 Installation description SP116 should be installed in retur...

Page 5: ...System working pressure 8 bar Safety valve response pressure 6 bar Ambient temperature 0 50 Input signals T1 T3 top part of water tank bottom part of water tank solar collector Output signals 3 auxili...

Page 6: ...size 450mm 310mm 150mm Max own consumption 3W Range of temperature measuring NTC10K 0 99 PT1000 0 199 Accuracy of temperature measuring 1 Power of pumps solar collector pump P1 and circulation pump P...

Page 7: ...on Setting three time periods Tank temperature As turning on off temperature value for auxiliary heating Solar system indication For SP116 SP226 only 1 system available Frost protection signal Overhea...

Page 8: ...e Press Confirm button to save the setting press Cancel button to cancel the setting 3 2 Temperature difference circulation function The solar control program works on the principle of temperature dif...

Page 9: ...time period Perform like above steps the other two time periods can be set Note If you want to shut off one of the three time periods you can set a same value for both start time and end time e g you...

Page 10: ...ating Press Choose Function button until displays on the screen Press Confirm button to save the setting and forbid auxiliary heating Press Choose Function button until displays on the screen Press Ca...

Page 11: ...the screen Press button to adjust the maximum collector temperature Default value 115 adjustable range 100 130 Press Confirm button to confirm the setting press Cancel button to quit this function 3 1...

Page 12: ...except time setting can be reset to the factory settings Press Choose Function button until displays on the screen Press Confirm button all of parameters will be reset to factory settings 3 15 Manual...

Page 13: ...ar system Check the pipeline and exhaust the air 6 Pump works but system doesn t have temperature difference meanwhile auxiliary heating function starts up Frost protection function is activated signa...