General TAB
This tab is used to read some general information within the controller
. To receive data click the “Tx”
button.
Application Name
Provided information on
the Hardware and
version.
Application Version
Provides information on
the Firmware. 101
indicates Version 1.01.
Application Build
Number
Increments every time
the firmware is built. 100
indicates V1.00.
Reset
Resets the
microcontroller when
pressed.
Supply Voltage (Vx10)
Reads the Voltage of the supply
x 10. So a value of 125 gives
12.5V.
Motor I (Ax10)
Reads the Motor Current x 10.
So a value of 42 gives 4.2A.
Controller Temp (degC)
Reads the controller
Temperature in degrees C. So a
value of 38 gives 38degC.
Analogue Value
Reads the Raw analogue value
of the Analogue input. Range
between 0-4095.
Pot Value
Reads the Raw Potentiometer
value of the onboard Pot Range
between 0-4095.
Enable Input Value
Reads the Enable input (Note
–
May be inverted from physical
input depending on “Invert Settings” Value
Direction Input Value
Reads Direction input (Note
–
May be inverted from physical input
depending on “Invert Settings” Value
Motor Power (W)
Reads the power to the motor.