7
Parameter list
The parameter list is in the chapter "Parameter list" in the operating instructions R-TBA12_01.
Parameters only used in the case of the ZAdyn4CA HY:
Control system menu
Parameter
Designation
Value range
Factory set-
ting
HY_Auto
Setting the tuning function phases
0:
Off
1:
1: empty 1
2:
2: empty x
3:
3: full 1
4:
4: full x
0...4
0
HY_O_A
Offset when the elevator starts up
Speed of pump at which the cabin moves
0...10000
2000
HY_t_A
Delay time when the elevator starts up
Time during which the value of HY_O_A is maintained
10...3000 ms
500 ms
HY_OFFS
Offset when the cabin arrives at the
fl
oor
Speed of pump at which the cabin no longer moves
0...10000
0
HY_LA_l
No-load current in the case of empty cabin
0.1...100.0 A
28.0 A
HY_LA_V
Speed gain in the case of fully loaded cabin
1...500
25
HY_NACH
Adjustment value
100...8000
2000
FIL_V_D
Filter time constant V_DCP
Determination of speed via DCP control
2...2048
16
INFO menu
DCP Ident - - - - - - - -
14
Info: xx
0101 / 010106 en
Load: ---% 211.0mm/s
Page 14: DCP-Ident
Information about the control system
Line 2:
Manufacturer
Line 3:
Software version of control system
Software date of the control system
Operating language set in the control system, display according to ISO639
The operating language of the ZAdyn4CA HY is automatically adapted.
Line 4 (only with DCP4):
current speed in mm/s
Quick Start Guide
ZAdyn4CA HY
Parameter list
R-TBA16_01-GB 1845 Index 003
Part.-No. 00163456-GB