Mounting Forced ventilation on top
1. Remove the brake terminal box (A) by loosening the two screws M4 (B) using the
screwdriver T20.
2. Loosen the hexagon socket screw M5 (5) with allen key SW and remove the
fi
xing plate (D ).
3. Attach the pre-assambled forced ventilation (1) to the provided threads (E) with two hexagon
socket screws M6 x 10 - 8.8 (2) and an allen key SW 5 at the motor housing.
4. Loosen the four hexagon head screws M6 x 8 - 8.8 (F) with a screw wrench SW 10 at the motor
terminal box and remove the terminal box plate (G).
5. Remove the blind plug (H) at the motor connection box.
2ULJLQDORSHUDWLQJLQVWUXFWLRQV
ZAtop
–
model series SM225.40B
Service and maintenance
A-TBA13_06-GB
Part.-No. 01009090-GB (
(8%'
)