Do not install distorted.
"
Do not apply any force (levering, bending). Above all, do not expose the rotor to any heavy
mechanical shocks.
"
Carry out the electrical connection in accordance with the enclosed wiring diagram.
"
Before starting installation, the drive must be checked for transport damage, especially the cables
have to be checked.
"
No welding must be carried out on the drive. The drive must not be used as an earthing point for
welding. Magnets and bearings could be destroyed.
"
The cooling-air
fl
ow around the motor must not be obstructed.
"
Keep at least 290 mm space between the brake and the wall (axial direction) to make access to the
encoder possible.
4.2
Patent situation
Pleasepayattention to the patent situation concerning the use of elevator machines in the
shaft. When using the ZAtop according to our installation examples there are no problems with
patents. In doubt please contact ZIEHL-ABEGG SE.
"
When installing the motor in the elevator shaft, the motor can be placed in the shaft head, with the
motor axle parallel to the nearest wall.
"
The motor must not be hanged over the cabin.
"
The motor should be fastened at the framework, Halfen cast-in channals or girders. The drive must
not be placed of fastened onto all four guide rails.
"
If the girder that supports the motor is fastened at one wall, the motor has to be installed on top of
the girder. A hanging motor is not permissible!
4.3
Mounting the drive unit
"
On the bottom side of the socket are 4 threads.
"
The motor has to be
fi
xed with 4 screws M16 - 8.8 at the mounting plate.
Tightening torque M16 - 8.8: 195 Nm
"
Screw-in depth at least 1.5 times of screw size. (minimum 24 mm, maximum 32 mm)
"
Fasten the screws crosswise in at least two steps to the required tightening torque.
"
The permissible unevenness for the mounting surface is 0.3 mm.
"
The mounting surface has to be rigid and robust enough to withstand the forces.
"
For the installation, insulating elements should be used to absorb the vibration.
4.4
Fastening the brake
The drive will be delivered with the mounted brake.
Brake
fi
xation in accordance with the brake operating instructions.
Information
An exchange of the brake can be carried out only with special centering tool. Please contact
the ZIEHL-ABEGG SE customer service in case of a brake exchange!
Mechanical installation
$7%$B*%
Part.-No. 01008166-GB (
EU-BD 845
)
7/68
2ULJLQDORSHUDWLQJLQVWUXFWLRQV
ZAtop
–
model series SM160.30B/40B