ZIEHL-ABEGG TTE-30AC Operating Instructions Manual Download Page 15

 

 L

-B

A

L-

E053

-G

B

-0

838

 I

nd

e

x 00

(78453E

 L

-B

A

L-

E053

-G

B

-0

838

 I

nd

e

x 00

(78453E

8.2 Assembly steps 

1.  Connect the wires to the terminals in the 

recessed part (observe the connection 
diagram in Section 8.3). 

2.  Install and screw the recessed part in the 

flush-type box (note the installation 
direction, terminals at the top). 

3.  Place the upper part on the recessed part 

(first attach the upper hook and then snap 
it down, see diagram). 

 
 
 
 
 
 
 

8.3 Connection diagram  

All connection terminals are equipped with slotted 
screws.  
A normal screwdriver with 3 mm blade can be used to 
tighten the screws. 
 

 

Connection diagram 

 

- 15 - 

 

8.2 Assembly steps 

4.  Connect the wires to the terminals in the 

recessed part (observe the connection 
diagram in Section 8.3). 

5.  Install and screw the recessed part in the 

flush-type box (note the installation 
direction, terminals at the top). 

6.  Place the upper part on the recessed part 

(first attach the upper hook and then snap 
it down, see diagram). 

 
 
 
 
 
 
 

8.3 Connection diagram  

All connection terminals are equipped with slotted 
screws.  
A normal screwdriver with 3 mm blade can be used to 
tighten the screws. 
 
 

Connection diagram 

 

 

- 15 - 

Summary of Contents for TTE-30AC

Page 1: ...L BAL E053 GB 0838 Index 001 78453E L BAL E053 GB 0838 Index 001 78453E Operating Instructions Clock Thermostat Type TTE 30AC Operating Instructions Clock Thermostat Type TTE 30AC...

Page 2: ...e clock G 21 11 Reset reset all settings 21 12 Technical data 23 Maintenance Service 24 Manufacturer reference Service information 24 2 Contens Chapter Exclusion of liability 3 Safety information 3 Tr...

Page 3: ...greed Damages resulting from such unauthorised uses will not be the liability of the manufacturer The user will assume sole liability 3 Exclusion of liability To allow for future developments construc...

Page 4: ...d for a maximum of 10 years LED display to show the provision of power Detection of breakage and short circuit at the external sensor 4 Transport storage Ziehl Abegg controllers are suitably packed at...

Page 5: ...12 comfort temperature 13 and control according to the time program 14 are also displayed when active using arrows in the display 15 5 2 Controls and display The bar at the upper display edge 1 displ...

Page 6: ...d to bring any other automatic control devices without their own clock into the energy saving mode This does not apply to the operating mode OFF The comfort temperature is set using the rotary button...

Page 7: ...gram at which time the temperature of the time program is resumed Pressing the PROG key causes a premature return to the time program 7 4 Functions in the normal display 4 1 Party function extend the...

Page 8: ...tomatically handles leap years The hour display flashes when the SET key is used to select the clock program item in the program menu 8 4 4 Locking the keyboard The keys can be locked to prevent unaut...

Page 9: ...11 00 24 00 comfort temperature Sa Su 5 00 8 00 10 00 24 00 comfort temperature These settings can be changed or extended as required 9 The or the key can now be used to set the hour After the hours h...

Page 10: ...the and keys for more than 10 seconds All switching times will be deleted irrevocably and the empty switching time will be displayed 10 Note The time programm heating can be changed in the operation m...

Page 11: ...l are not automatically detected or removed The user himself must delete such switching times when free switching times are required 11 5 3 5 Adding a new switching time After selecting the empty swit...

Page 12: ...ntrol device deletes the vacation period and returns automatically to the menu selection Press the PROG key to exit the program menu 12 5 4 Vacation function The device provides with the UrLb menu ite...

Page 13: ...e contact your electrician so that he can find the cause Warning The device operates with line voltage You must not open it yourself 13 6 Failure causes and their rectification 6 1 No display Should a...

Page 14: ...the sensor can record the temperature of the component to be measured medium as accurately as possible do not install in edge areas 14 Installation and commissioning guide 7 Fields of application The...

Page 15: ...terminals are equipped with slotted screws A normal screwdriver with 3 mm blade can be used to tighten the screws Connection diagram 15 8 2 Assembly steps 4 Connect the wires to the terminals in the r...

Page 16: ...nd arrow on the comfort temperature symbol and after several seconds the actual temperature on the selected sensor will be displayed 16 8 4 Range limitation If the complete setpoint adjustment range o...

Page 17: ...ctivate the daylight saving setting G running accuracy of the clock Correction value for the running accuracy in seconds per day s d 17 10 Initial settings in the parameter menu Note Because under som...

Page 18: ...al sensor de energized open I o External sensor de energized open E o Internal sensor Cooling External sensor de energized open IE o 18 10 1 Software version This menu item can be used to fetch the cu...

Page 19: ...e i e switching occurs immediately when the limit value is exceeded or undershot Similarly the minimum switching duration is ignored 19 10 4 Switching difference d This parameter defines the switching...

Page 20: ...eactivated switching is done as specified by the time program The initial heating optimization is deactivated as factory setting OFF 20 10 8 Temperature at the external sensor S If an operating mode t...

Page 21: ...clock The automatic control device then performs its display test and provides the clock setting for commissioning see Commissioning 21 10 12 Gradient of the initial heating optimization r This menu i...

Page 22: ...L BAL E053 GB 0838 Index 001 78453E L BAL E053 GB 0838 Index 001 78453E 22 22...

Page 23: ...ety class II in accordance with DIN EN 60730 1 Weight Approx 120g No safety clearance EN 60730 1 for switching of safety low voltage 23 12 Technical data Typ TTE 30AC 325003 Temperature ranges 5 30 C...

Page 24: ...ition you can download it from our homepage Download Ventilation Technology Topic Control Engineerin Document type General documents 24 Maintenance Service Keep controller free of dust Check the termi...

Reviews: