5.3.5 Adding a new switching time  

After selecting the empty switching time, press the SET key. 

The hour display flashes and can be 
changed with the + and – keys. Press 
the SET key to confirm the hour setting; 
the minute value then starts to flash. 

This value can now be changed in 10-
minute intervals with the + and – keys and confirmed with the 
SET key. 

The same procedure is used for the day selection and for the 
temperature selection. In the case of the day selection, the 
weekdays are shown first individually and then as groups Sa-
Su, Mo-Fr, Mo-Sa, Mo-Su. 

Note

:   Groups of days. If a group of days is selected, an 

individual program item with the specified time and the 
temperature level is created for each selected day of 
the group. The complete grouping cannot be changed, 
rather only the individual program items can be 
changed. 

After the last confirmation with SET, the changed switching 
time will be stored and the next switching time in chronological 
sequence displayed. 

5.3.6 Cancelling time program settings  

The PROG key can be used to cancel the settings for a 
switching time currently open for processing. Any previous 
changes will not be stored. Press the PROG key again to 
return to the program menu or to the normal display.

 

5.3.7 Special programming cases  

No empty switching time will be offered if no further switching 
time is available. 

If a group of days is programmed although insufficient 
switching times are available, 

FULL

 and the number of 

available switching times will be displayed. This allows the 
user to decide how many switching times are missing or 
whether he can make his required program using specific 
days. 

If a group of days matches an existing switching time, the 
existing switching time will be overwritten without prompt. 

If a new switching time is placed at the time of an existing 
switching time, the existing switching time will be overwritten 
without prompt. 

If an existing switching time is changed and placed at a time 
already occupied by another existing switching time, the 
existing switching time will be overwritten without prompt. 

Redundant switching times (switching times in the time 
program that do not cause any change of the temperature 
level) are not automatically detected or removed. The user 
himself must delete such switching times when free switching 
times are required.

 

- 11 - 

 

5.3.5 Adding a new switching time  

After selecting the empty switching time, press the SET key. 

The hour display flashes and can be 
changed with the + and – keys. Press 
the SET key to confirm the hour setting; 
the minute value then starts to flash. 

This value can now be changed in 10-
minute intervals with the + and – keys and confirmed with the 
SET key. 

The same procedure is used for the day selection and for the 
temperature selection. In the case of the day selection, the 
weekdays are shown first individually and then as groups Sa-
Su, Mo-Fr, Mo-Sa, Mo-Su. 

Note

:   Groups of days. If a group of days is selected, an 

individual program item with the specified time and the 
temperature level is created for each selected day of 
the group. The complete grouping cannot be changed, 
rather only the individual program items can be 
changed. 

After the last confirmation with SET, the changed switching 
time will be stored and the next switching time in chronological 
sequence displayed. 

5.3.6 Cancelling time program settings  

The PROG key can be used to cancel the settings for a switching 
time currently open for processing. Any previous changes will not 
be stored. Press the PROG key again to return to the program 
menu or to the normal display.

 

5.3.7 Special programming cases  

No empty switching time will be offered if no further switching 
time is available. 

If a group of days is programmed although insufficient 
switching times are available, 

FULL

 and the number of 

available switching times will be displayed. This allows the 
user to decide how many switching times are missing or 
whether he can make his required program using specific 
days. 

If a group of days matches an existing switching time, the 
existing switching time will be overwritten without prompt. 

If a new switching time is placed at the time of an existing 
switching time, the existing switching time will be overwritten 
without prompt. 

If an existing switching time is changed and placed at a time 
already occupied by another existing switching time, the 
existing switching time will be overwritten without prompt. 

Redundant switching times (switching times in the time 
program that do not cause any change of the temperature 
level) are not automatically detected or removed. The user 
himself must delete such switching times when free switching 
times are required.

 

- 11 - 

Summary of Contents for TTE-30AC

Page 1: ...L BAL E053 GB 0838 Index 001 78453E L BAL E053 GB 0838 Index 001 78453E Operating Instructions Clock Thermostat Type TTE 30AC Operating Instructions Clock Thermostat Type TTE 30AC...

Page 2: ...e clock G 21 11 Reset reset all settings 21 12 Technical data 23 Maintenance Service 24 Manufacturer reference Service information 24 2 Contens Chapter Exclusion of liability 3 Safety information 3 Tr...

Page 3: ...greed Damages resulting from such unauthorised uses will not be the liability of the manufacturer The user will assume sole liability 3 Exclusion of liability To allow for future developments construc...

Page 4: ...d for a maximum of 10 years LED display to show the provision of power Detection of breakage and short circuit at the external sensor 4 Transport storage Ziehl Abegg controllers are suitably packed at...

Page 5: ...12 comfort temperature 13 and control according to the time program 14 are also displayed when active using arrows in the display 15 5 2 Controls and display The bar at the upper display edge 1 displ...

Page 6: ...d to bring any other automatic control devices without their own clock into the energy saving mode This does not apply to the operating mode OFF The comfort temperature is set using the rotary button...

Page 7: ...gram at which time the temperature of the time program is resumed Pressing the PROG key causes a premature return to the time program 7 4 Functions in the normal display 4 1 Party function extend the...

Page 8: ...tomatically handles leap years The hour display flashes when the SET key is used to select the clock program item in the program menu 8 4 4 Locking the keyboard The keys can be locked to prevent unaut...

Page 9: ...11 00 24 00 comfort temperature Sa Su 5 00 8 00 10 00 24 00 comfort temperature These settings can be changed or extended as required 9 The or the key can now be used to set the hour After the hours h...

Page 10: ...the and keys for more than 10 seconds All switching times will be deleted irrevocably and the empty switching time will be displayed 10 Note The time programm heating can be changed in the operation m...

Page 11: ...l are not automatically detected or removed The user himself must delete such switching times when free switching times are required 11 5 3 5 Adding a new switching time After selecting the empty swit...

Page 12: ...ntrol device deletes the vacation period and returns automatically to the menu selection Press the PROG key to exit the program menu 12 5 4 Vacation function The device provides with the UrLb menu ite...

Page 13: ...e contact your electrician so that he can find the cause Warning The device operates with line voltage You must not open it yourself 13 6 Failure causes and their rectification 6 1 No display Should a...

Page 14: ...the sensor can record the temperature of the component to be measured medium as accurately as possible do not install in edge areas 14 Installation and commissioning guide 7 Fields of application The...

Page 15: ...terminals are equipped with slotted screws A normal screwdriver with 3 mm blade can be used to tighten the screws Connection diagram 15 8 2 Assembly steps 4 Connect the wires to the terminals in the r...

Page 16: ...nd arrow on the comfort temperature symbol and after several seconds the actual temperature on the selected sensor will be displayed 16 8 4 Range limitation If the complete setpoint adjustment range o...

Page 17: ...ctivate the daylight saving setting G running accuracy of the clock Correction value for the running accuracy in seconds per day s d 17 10 Initial settings in the parameter menu Note Because under som...

Page 18: ...al sensor de energized open I o External sensor de energized open E o Internal sensor Cooling External sensor de energized open IE o 18 10 1 Software version This menu item can be used to fetch the cu...

Page 19: ...e i e switching occurs immediately when the limit value is exceeded or undershot Similarly the minimum switching duration is ignored 19 10 4 Switching difference d This parameter defines the switching...

Page 20: ...eactivated switching is done as specified by the time program The initial heating optimization is deactivated as factory setting OFF 20 10 8 Temperature at the external sensor S If an operating mode t...

Page 21: ...clock The automatic control device then performs its display test and provides the clock setting for commissioning see Commissioning 21 10 12 Gradient of the initial heating optimization r This menu i...

Page 22: ...L BAL E053 GB 0838 Index 001 78453E L BAL E053 GB 0838 Index 001 78453E 22 22...

Page 23: ...ety class II in accordance with DIN EN 60730 1 Weight Approx 120g No safety clearance EN 60730 1 for switching of safety low voltage 23 12 Technical data Typ TTE 30AC 325003 Temperature ranges 5 30 C...

Page 24: ...ition you can download it from our homepage Download Ventilation Technology Topic Control Engineerin Document type General documents 24 Maintenance Service Keep controller free of dust Check the termi...

Reviews: