Operating conditions

Do not operate fans in an explosive atmosphere.

Duty type of motor/fan

Continuous operation with occasional starts (S1) 
according to DIN EN 60034-1:2011-02.
Occasional starting between -40 

°

C and -25 

°

C is 

permissible.
Continuous operation below -25 

°

C only with special 

bearings for refrigeration applications on request. 

Permissible minimal and maximal ambient temperature for 
operation

Please refer to the technical documentation of the 
product for the minimum and maximum ambient 
temperature valid for the respective fan.
Operation below -25 

°

C as well as partial load operation 

for refrigeration applications is only possible with 
special bearings for refrigeration applications on 
request. If special bearings for refrigeration applications 
are installed in the fan, please observe the permissible 
maximum temperatures in the technical documentation 
of the product. 

Any use below -10 

°

C is dependent on not being 

subjected to unusual, sudden or mechanical loads or 
stresses on the material (see minimal permissible 
ambient temperature).

ZIEHL-ABEGG Centrifugal fans are suitable for operation 
with frequency inverters when the following points are 
complied with: 

Between the inverter and the motor, sinusoidal 

lters 

should be incorporated which are 

effective for all 

phases

 (sinusoidal output voltage, phase against 

phase, phase against protective conductor) as offered 
by manufacturers. Please ask for our technical informa-
tion L-TI-0510.

du/dt 

lters (also called motor or suppression 

lters) cannot be used in place of sinusoidal 

lters.

When using sinusoidal 

lters, screened motor leads, 

metal terminal boxes and a second earth connection to 
the motor can, if necessary, be omitted. Check-back by 
the supplier of the sinusoidal 

lter.

If the operational leakage current exceeds 3.5 mA, 
earthing in compliance with DIN EN 50 178, art. 5.2.11.1 
must be provided.

When speed controlling through electronic voltage reduc-
tion (phase control), depending on the installation situa-
tion, increased noise formation caused by resonances can 
occur. In such cases we recommend the use of the Fcon-
trol frequency changer with integrated sine 

lter.

We cannot guarantee that competitive makers of 
voltage control devices and frequency converters will 
function properly and not damage the motor when 
used for rotational-speed control of our fans

A-rated sound power levels of over 80 dB(A) are possible, 
see product catalogue.

IP55 fans with a seal which is rubbing may cause addi-
tional noise.

Corrosion is possible at the cutting edges on sendzimir 
galvanised parts. 

İş

letim Ko

ş

ullar

ı

Ventilatoren , patlay

ı

c

ı

 ortamlarda i

ş

letilmemelidir.

Motorun/fan

ı

n i

ş

letim t

ü

r

ü

DIN EN 60034-1:2011-02 uyar

ı

nca arada s

ı

rada 

çal

ış

t

ı

rmal

ı

 (S1) s

ü

rekli i

ş

letim.

-40 

°

C ile -25 

°

C aras

ı

nda arada s

ı

rada çal

ış

t

ı

rmaya izin 

verilir.
-25 

°

C'nin alt

ı

nda s

ü

rekli i

ş

letim sadece so

ğ

uk 

uygulamalar için talep 

ü

zerine sunulan özel yataklarla 

m

ü

mk

ü

nd

ü

r.

İş

letim için m

ü

saade edilen minimum ve maksimum ortam 

s

ı

cakl

ığı

– İ

lgili fan için geçerli minimum ve maksimum ortam 

s

ı

cakl

ığı

 için l

ü

tfen 

ü

r

ü

n

ü

n teknik dok

ü

mantasyonuna 

bak

ı

n. 

So

ğ

uk uygulamalarda -25 

°

C'nin alt

ı

nda i

ş

letim ve k

ı

smi 

y

ü

k i

ş

letimi sadece so

ğ

uk uygulamalar için talep 

ü

zerine sunulan özel yataklarla m

ü

mk

ü

nd

ü

r. Fana özel 

so

ğ

uk yataklar tak

ı

l

ı

ysa, l

ü

tfen 

ü

r

ü

n

ü

n teknik 

dok

ü

mantasyonunda belirtilmi

ş

 olan, izin verilen 

maksimum s

ı

cakl

ı

klar

ı

 dikkate al

ı

n.

-10 

°

C'nin alt

ı

nda ortam s

ı

cakl

ı

klar

ı

nda kullan

ı

m için 

malzemede s

ı

ra d

ışı

, darbe 

ş

eklinde veya mekanik 

zorlanma ve y

ü

klemelerin önlenmesi ön ko

ş

uldur (bkz. 

izin verilen asgari ortam s

ı

cakl

ığı

).

ZIEHL-ABEGG Radyal fanlar, a

ş

a

ğı

da belirtilen hususlara 

dikkat edilmesi halinde frekans dön

üş

t

ü

r

ü

c

ü

lerde kullan

ı

için uygundur: 

Frekans dön

üş

t

ü

r

ü

c

ü

 ile motor aras

ı

na, baz

ı

 frekans 

dön

üş

t

ü

r

ü

c

ü

s

ü

 

ü

reticileri taraf

ı

ndan sunuldu

ğ

ş

ekli ile 

t

ü

m kutuplarda etkili

 bir sin

ü

ltresi (Sin

ü

s biçiminde 

ç

ı

k

ış

 gerilimi! Faza kar

şı

l

ı

k faz, faza kar

şı

l

ı

k koruma 

iletkeni) monte edilmelidir. Konuyla ilgili olarak L-TI-
0510 say

ı

l

ı

 teknik bilgi dok

ü

man

ı

m

ı

z

ı

 talep ediniz.

Sin

ü

ltrelerinin yerine du/dt 

ltreleri (motor veya 

izolasyon 

ltresi olarak da adland

ı

r

ı

lmaktad

ı

r) 

kullan

ı

lmamal

ı

d

ı

r.

Sin

ü

ltreleri kullan

ı

ld

ığı

nda, (sin

ü

ltresi 

tedarikçisinin gör

üşü

 al

ı

narak) ekranlamal

ı

 motor giri

ş

 

kablolar

ı

, metal terminal kutusu kullan

ı

lmas

ı

 ve 

motordaki ikinci topraklama iletkeni ba

ğ

lant

ı

s

ı

n

ı

yap

ı

lmas

ı

 

ş

art de

ğ

ildir.

3,5  mA

lik i

ş

letime ba

ğ

l

ı

 kaçak ak

ı

m a

şı

ld

ığı

nda, 

topraklama ile ilgili ko

ş

ullar DIN  EN  50 178, Madde 

5.2.11.1

e uygun hale getirilmelidir.

Elektronik gerilim d

üş

mesi sonucu devir say

ı

s

ı

 

yönetiminde (faz yönetimi) montaj 

ş

ekline göre rezonans 

sonucu g

ü

r

ü

lt

ü

 olu

ş

umu gör

ü

lebilir. Bu durumda entegre 

sin

ü

ltreli frekans dön

üş

t

ü

r

ü

c

ü

 Fcontrol kullan

ı

lmas

ı

 

tavsiye edilir.

Ventilatoren

‘ı

m

ı

z

ı

n devir say

ı

s

ı

n

ı

 kontrol etmek için 

farkl

ı

 

ü

reticilere ait gerilim kontrol cihazlar

ı

 ve frekans 

dön

üş

t

ü

r

ü

c

ü

ler kullan

ı

ld

ığı

nda, sorunsuz bir çal

ış

may

ı

 

garanti edemeyece

ğ

imiz gibi, motorda meydana 

gelebilecek hasarlar için hiçbir sorumluluk 

ü

stlenmeyiz.

80 dB(A) 

ü

zeri A a

ğı

rl

ı

kl

ı

 ses bas

ı

nç seviyesi m

ü

mk

ü

nd

ü

r, 

bkz. 

ü

r

ü

n katalo

ğ

u.

Temasl

ı

 contaya sahip IP55 Ventilatoren, ilave olarak 

g

ü

r

ü

lt

ü

ye neden olabilmektedir.

Sendzimir yöntemiyle çinko kaplanm

ış

 yap

ı

 parçalar

ı

nda, 

kesilen kenarlarda korozyon m

ü

mk

ü

nd

ü

r.

7

T

ü

rkçe

english

00280351-GB-TR

L-BAL-005-TR-1939-Index 

014

Summary of Contents for DN Series

Page 1: ...from the age of 14 up In the event of deviations further structural protective measures must be taken for safe opera tion Montaj talimatı Radyal ve diyagonal fanlar İçerik Bölüm Sayfa Kullanım 1 Emniyet Uyarıları 2 ErP Direktifine dair bilgi 3 Taşıma Depolama 4 Montaj 5 İşletim Koşulları 7 Devreye 8 Servis Bakım Temizlik 9 Tasfiye Geridönüşüm 10 Üretici 10 Servis adresi 10 Aşağıdaki kriterlere uyulm...

Page 2: ...ced insulation nor by connection to safety earth in accordance with EN 60204 1 therefore the motor fan must be installed so that it is not touchable Emniyet Uyarıları Bu montaj talimatı ürünün bir parçasıdır ve her zaman kolayca ulaşılabilir bir şekilde saklanmalıdır Vantilatörler hava veya hava benzeri karışımların taşınması için tasarlanmıştır Patlama tehlikesi olan alanlarda gaz buhar sis veya ...

Page 3: ... be found on www ziehl abegg de search key ErP ErP Direktifine dair bilgi ZIEHL ABEGG SE firması 2009 125 EG Direktifin yürütülmesine dair 30 Mart 2011 tarihinde komisyonun EU No 327 2011 sayılı tebliğ bundan sonra ErP tebliği diye anılacaktır uyarınca AB içinde belirli vantilatörlerin kullanım alanının belirli koşullara bağlı olduğuna işaret eder Yalnızca ErP tebliğinin gereklilikleri söz konusu van...

Page 4: ... Koruyucu eldiven ve ayakkabı giyin Fanı fanları orijinal ambalajlarında veya daha büyük boyutlu fanları uygun taşıma araçları kullanarak öngörülen taşıma tertibatlarında gövde flanşı L tipi montaj braketi halkalı cıvataların vidalanması için motor gövdesinde delikler taşıyın GR yapı tipi Fan ünitesi sadece uygun bir kaldırma aracı Yük traversi kullanılarak kaldırılmalı ve taşınmalıdır Halatın veya...

Page 5: ...ow Montaj Pervane vantilatör veya balans ağırlığını gevşetme Montajı ve elektrik bağlantısını yalnızca bırakın eğitimli uzman personel Koruyucu eldiven ve ayakkabı giyin Sisteme ilişkin montaj ve emniyet uyarılarının geçerli standartlar ve yönetmelikler DIN EN ISO 12100 13857 ile aynı doğrultuda olup olmaması tamamen sistemin veya tesisin üreticisinin sorumluluğundadır RE RH RM yapı tipine sahip f...

Page 6: ...rain hole if available must be open Dahili olarak bağlanmış termik şalter Harici bağlantı mümkün değildir veya gerekmemektedir Dikkat Termik şalterler yüksek sıcaklık nedeniyle attığında belli bir soğumanın ardından tekrar kendiliğinden devreden çıkmaktadır Bu sırada fanın çalışmaya başlaması mümkündür Dışarı çıkartılmış olan termik röleler kontrol akımı devresine bir arıza durumunda soğuma gerçek...

Page 7: ...arts İşletim Koşulları Ventilatoren patlayıcı ortamlarda işletilmemelidir Motorun fanın işletim türü DIN EN 60034 1 2011 02 uyarınca arada sırada çalıştırmalı S1 sürekli işletim 40 C ile 25 C arasında arada sırada çalıştırmaya izin verilir 25 C nin altında sürekli işletim sadece soğuk uygulamalar için talep üzerine sunulan özel yataklarla mümkündür İşletim için müsaade edilen minimum ve maksimum o...

Page 8: ...o erratic operation unbalanced e g caused by transporta tion damage or improper use can lead to failure Devreye alınmasından önce kontrol edin Montaj ve elektrik tesisatı kurallara uygun olarak yapıldı mı Elektrik bağlantısı devre şeması uyarınca kuruldu terminal kutusunda devre şeması kablo veya duvar halkası kablo tipinde Dönüş yönü fan kanadı veya fan gövdesi üzerindeki dönüş yönü ok işareti il...

Page 9: ...ntilator üzerinde tehlike bölgesinde yapılan tüm çalışmalarda şu hususlara dikkat edilmelidir Bu çalışmalar sadece bu konuda eğitim almış uzman personel tarafından yapılmalıdır Emniyet ve çalışma yönetmelikleri DIN EN 50 110 IEC 364 dikkate alınmalıdır Ventilator çalışır durumdayken bakım çalışması yapılmamalıdır Akım devresi kesilmiş ve tekrar çalıştırılmaya karşı emniyet altına alınmış Gerilim b...

Page 10: ... the homepage at www ziehl abegg com for a list of our subsidiaries worldwide Tasfiye Geridönüşüm Tasfiye işlemi yasal düzenlemeler doğrultusunda tekniğe uygun ve doğaya zarar vermeden yerine getirilmelidir Üretici Ürünlerimiz uluslararası geçerliliğe sahip yönetmeliklere uygun olarak imal edilmiştir Ürünlerimizin kullanımına yönelik olarak sorularınız olduğunda veya özel uygulamalar planladığınızda...

Page 11: ...eri Risk değerlendirmesi ve risk azaltma EN ISO 13857 2008 Makinelerde Güvenlik Kol ve Bacakların Ulaşabileceği Bölgelerde Tehlikenin Önlenmesi için Güvenlik Mesafeleri Uyarı EN ISO 13857 2008 standardına uyulması sadece teslimat kapsamına ait olduğu sürece monte edilmiş temas korumasına ilişkindir Ek VII B tarafından öngörülen özel teknik dokümanlar oluşturulmuştur ve eksiksiz mevcuttur Önemli te...

Page 12: ...d risk reduction EN ISO 13857 2008 Safety of machinery safety distances to prevent danger zones being reached by the upper limbs Note The maintenance of the EN ISO 13857 2008 relates only to the installed accidental contact protection provided that it is part of the scope of delivery The specific technical documentation in accordance with Appendix VII B has been written and is available in its enti...

Reviews: