35
FAULTS AND TROUBLESHOOTING
HYDRAULIK
Malfunction
Cause
Remedy
Pickup cannot be
raised
Insufficient amount of hydraulic oil
Refill oil
Lifting power too low
Additional lifting cylinder required
The hydraulic func-
tions of the pickup do
not work
Hydraulic connections have no flow
Check connections/cou-
plings/screw connections
Lack of pressure in the hydraulic system
Check pressure, increase if per-
mitted
Insufficient amount of hydraulic oil
Refill oil
DRIVE
Malfunction
Cause
Remedy
The drive is switched
on, but the conveyor
belt is not turning.
Hydraulic connections have no flow
Check connections/cou-
plings/screw connections
Lack of pressure in the hydraulic system
Check pressure, increase if per-
mitted
Insufficient amount of hydraulic oil
Refill oil
Pickup stops during
use
Overload
Adjust working speed
AUGER
Malfunction
Cause
Remedy
Conveyor screw stops
Overload
Reduce amount of material straw
percentage too high
Drive
Check chain and clutch
Original combine harvester splash panel
mounted in front of the intake channel
Remove splash panel