49
4
the Zibro authorized installer is fully trained for all maintenance tasks. therefore
maintenance to the stove must only be done by Zibro authorized installer using
Zibro agreed parts.
d.3.1 changing the door seal
Remove the seal from its seat and replace it. fasten it using high temperature silicon.
d.3.2 checking room air circulation fan
the fan can be checked after removal of the air filter. make sure the stove is dis-
connected from electrical power supply. the heater needs to be laid on its rear side
to access the fan for cleaning. Remove the majolica side tiles at both sides of the
stove to avoid cracks. disconnect the chimney. clean of the inner side of the fan
with a soft brush and a vacuum cleaner.
d.4 spare parts
only use original by Zibro agreed spare parts.
to have your spare parts order been taken care of in the most efficient way, always
issue the following information upon ordering parts:
•
serial number of the stove for which the specific part is mentioned
•
number of the part in the exploded view
•
part name (also mentioned in English language in exploded view)
•
quantity
Picture 11, the door seal
Picture 12 the
room air circulation fan.