Device info
zNID 24xx Series Configuration Guide
67
Figure 41: GPON alarm example, Loss of Signal
Triplexer Temp
Temperature of the triplexer device, in degrees C (and F).
Voltage
Nominal triplexer operating voltage.
Table 17: GPON alarms
UI Label
Description
Auto-Power Control
Failure
Auto-Power Control (APC) is the ability to adjust to
variations in optical power. APC failure is the inability
to properly adjust.
Loss of Signal
No input signal detected. Make sure fiber is plugged in.
Loss of Link
The link has been lost
Loss of Frame
Framing has been lost
GEM LCD
Loss of GEM Channel Delineation.
Failed Signal
Bit Error Rate exceeds 10E-5
Degraded Signal
Bit Error Rate exceeds 10E-6
Msg Error Msg
Unknown PLOAM message received.
Deactivated
Received Deactivate on ONU.
Disabled
Disabled by the OLT or the ONU Serial Number is not
configured on the OLT.
Physical Equipment
Error
Indicates possible hardware problems.
Table 16: GPON link status
UI Label
Description
Summary of Contents for zNID-GE-2402
Page 12: ...About This Guide 12 zNID 24xx Series Configuration Guide ...
Page 18: ...zNID 24xx Series 18 zNID 24xx Series Configuration Guide ...
Page 84: ...Management 84 zNID 24xx Series Configuration Guide Figure 57 View audit log ...
Page 199: ...VLANS zNID 24xx Series Configuration Guide 199 Figure 157 Configuration of VLAN settings ...
Page 208: ...Configuration 208 zNID 24xx Series Configuration Guide ...
Page 220: ...Troubleshooting tests 220 zNID 24xx Series Configuration Guide ...
Page 223: ...Voice zNID 24xx Series Configuration Guide 223 Voice Figure 175 ...
Page 226: ...Index 226 zNID 24xx Series Configuration Guide ...