background image

 

 

 

Package Contents 

Unpack and Inspect the network extender. If there is any visible damage, do not 
attempt to connect the device. Contact your sales or service provider. 

Release Notes 

Before installing your network extender, review the release notes for your 
model. These are available on the “Service and Support” page under the 
documentation heading at the Zhone website. 

http://www.zhone.com/support/manuals/net_ext_manuals#rnotes

 

 

Summary of Contents for ETHX-DS3-1-LT

Page 1: ...1 LT and ETHX DS3 2 LT 4 Package Contents 5 Release Notes 5 Powering Up the Network Extender 6 Connecting the DS3 Lines 8 Connecting the Ethernet Lines 9 LED Indicators 10 Web Interface 12 Command Line Interface 17 Resetting the Network Extender to Factory Defaults 19 Specifications 22 EMI Notices 23 NEBS Compliance 23 Service and Repair 24 Important Safety Instructions 25 Product Documentation On...

Page 2: ... including any copy of either If you have executed a separate written agreement covering the Software supplied to you under this purchase such separate written agreement shall govern Zhone Technologies Inc Zhone grants to you and you Licensee agree to accept a personal non transferable non exclusive right without the right to sublicense to use the Software solely as it is intended and solely as in...

Page 3: ...tion to another 6 IN NO EVENT WILL ZHONE BE LIABLE TO LICENSEE FOR ANY CONSEQUENTIAL INCIDENTAL PUNITIVE OR SPECIAL DAMAGES INCLUDING ANY LOST PROFITS OR LOST SAVINGS LOSS OF BUSINESS INFORMATION OR BUSINESS INTERRUPTION OR OTHER PECUNIARY LOSS ARISING OUT OF THE USE OR INABILITY TO USE THE SOFTWARE WHETHER BASED ON CONTRACT TORT WARRANTY OR OTHER LEGAL OR EQUITABLE GROUNDS EVEN IF ZHONE HAS BEEN ...

Page 4: ...ETHX DS3 2 LT can be connected in any combination so long as every connection pairs a provider and a subscriber unit ETHX DS3 x LT units are shipped from the factory configured as provider units This configuration can be changed via web management If you wish to connect a pair of new units in a point to point network configuration one of the units must be re configured to the subscriber mode See t...

Page 5: ...nnect the device Contact your sales or service provider Release Notes Before installing your network extender review the release notes for your model These are available on the Service and Support page under the documentation heading at the Zhone website http www zhone com support manuals net_ext_manuals rnotes ...

Page 6: ... end of the ground wire The bare stripped ends of the ground conductor must be coated with an anti oxidation compound before crimp connections are made to connector terminals Crimp a connector of a suitable size to fit the ground lug on the chassis on to the prepared wire end Use only listed connection terminals on the ground wire 4 The ground lug on the unit has two nuts with a star washer betwee...

Page 7: ...or use in powering the unit Using any other AC power supply could cause the unit to be non compliant to emissions and safety regulations 2 Plug the power terminal strip into the power connector on the back of the unit 3 Plug the AC power cord into the AC power supply and into a compatible AC outlet 4 Verify that the Power LED on the front of the network extender is illuminated ETHX DS3 2 LT ...

Page 8: ...twork extender Two DS3 lines also act as a backup should one of the lines become disabled A network extender can only establish loop bonded connections with other Zhone equipment with the loop bonding feature Procedure 1 Plug the DS3 cables into the DS3 BNC 75 ohm connectors on the back of the network extender Each DS3 connection requires two coax cables one for transmit Tx and one for receive Rx ...

Page 9: ...ecting the Ethernet Lines The 10 100BaseT Ethernet ports can auto negotiate speed and duplex mode in accordance with the remote equipment to which it is connected or Ethernet speed and duplex mode configurations can be configured using web management See Web Interface on page 12 For the best connection results the remote devices PCs hubs or switches should be set to auto negotiate speed and duplex...

Page 10: ...t Illuminated No Ethernet connection The Ethernet 100 and Act LEDs will remain unlit by default Solid Amber Full duplex Ethernet connection Not Illuminated No link or functioning at half duplex 10 100 Ethernet Connections Duplex Collision Pulsing Amber Half duplex link with packet collisions Solid Green 100 Mbps Ethernet connection is established If the Ethernet 100 LED is illuminated the Ethernet...

Page 11: ...onnection has been lost the unit may no longer be receiving data from its partner network extender Blue alarm The unit s partner network extender has lost a connection with an intermediate device and has LOS or RAI Flashing Amber Data is being transmitted DS3 Connections Tx Ports 1 or 1 2 Not Illuminated No data is being transmitted Flashing Amber Data is being received DS3 Connections Rx Ports 1 ...

Page 12: ...his procedure is not necessary if you are connecting directly to the Ethernet ports on either the provider or subscriber units 1 Get the MAC address from the bottom label of the subscriber unit 2 Open a command prompt Click on Start and then Run In the Open window type CMD and press Enter At the command line type arp s 192 168 254 251 xx xx xx xx xx xx where the IP address is the default address o...

Page 13: ...mple to configure the IP address under Windows XP Procedure 1 In the Windows task bar click on the Start button and then click on Control Panel 2 Double click on the Network Connections icon 3 In the LAN or High Speed Internet window right click on the icon corresponding to your network interface card NIC and select Properties Often this icon is labeled Local Area Connection The Local Area Connect...

Page 14: ...ld and press Enter The web server opening screen appears 10 Click on Next The login dialog box appears Log in using Username superuser Password Password Note Username and password are case sensitive Enter them exactly as shown The web management home page appears ...

Page 15: ...mes Pro Sub Cfg Provider or Subscriber mode IGMP IGMP configuration MAC Display only Search IGMP or MAC Srvr Password Time out Set Change web management Password Time out DSLAM Users Display only Show Help Provides a link to on line help via the Internet Refresh Screen Refreshes web management screen Ethernet Connections Lnk Act LEDs Ethernet Duplex Mode Speed and Native VLAN ID DS3 Connections Ln...

Page 16: ...unit It will display either the word Provider or Subscriber indicating the current mode of the unit To make a change click on the Pro Sub Cfg button which is located just left of center on the graphical view of the front of the unit This will bring up the following screen Click on the button associated with the desired mode for the unit Then click on the submit button Go back to the home page and ...

Page 17: ...dows you may need to install a Telnet client Connecting a PC Directly Initial configuration using the CLI requires a direct physical connection from your PC to the COM port of the network extender you are configuring However the web interface is recommended for subsequent configuration Procedure 1 Plug a DB9 to 8 pin modular adapter into the RS232 serial port on your PC See DB9 to 8 Pin Modular Ad...

Page 18: ...set slot 1 ip_address 137 182 10 251 set slot 1 subnet_mask 255 255 255 0 set slot 1 default_gateway 137 182 10 10 The Subscriber unit in this example can now be managed with web management by attaching a PC to one of the network extender s Ethernet ports or through the DS3 ports by opening the address 137 182 10 251 in a web browser Option 2 After you have logged in enter H for Help to list the a...

Page 19: ...ed paper clip to gently push the button and let it go 2 Wait a few seconds until the DS3 Port LEDs flash green starting at Port 1 and ending at Port 2 on an ETHX DS3 2 LT unit Gently push the reset button again within 3 seconds of port 1 or port 2 LED illumination NVRAM is cleared and all configurations on the unit are set to the factory defaults Note As mentioned previously the factory default fo...

Page 20: ...20 Connector Pin Assignments Ethernet Pin Assignments Table 3 Ethernet Pin Assignments Pin Function Pin 1 Rx Pin 2 Rx Pin 3 Tx Pin 4 not used Pin 5 not used Pin 6 Tx Pin 7 not used Pin 8 not used ...

Page 21: ...shown Table 4 DB9 to 8 Pin Modular Adapter Pinouts Pin 8 Pin Modular Port Direction PC RS232 Serial Port Pin 1 Transmit Data TxD RxD Receive Data 2 2 Data Set Ready DSR RTS Request to Send 7 4 Receive Data RxD TxD Transmit Data 3 5 Ground GN D GND Ground 5 6 Data Terminal Ready DTR CTS Clear to Send 8 Pins not shown are unused ...

Page 22: ...8 position jacks Operating Environment Temperature 32 F to 122 F 0 C to 50 C Non operating temperature 40 F to 158 F 40 C to 70 C Humidity 5 to 95 non condensing Altitude 200 ft to 16 500 ft 60 m to 5 000 m Power ETHX DS3 1 LT 48 VDC 0 2 A 11 W ETHX DS3 2 LT 48 VDC 0 3 A 15 W Protocols Supported Transparent 802 1D Bridging DS3 Line Code C bit parity unchannelized DS3 Regulatory Compliance EMC FCC ...

Page 23: ...y must be installed per the installation instructions Canada EMI Notice This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada NEBS Compliance The equipment has been tested and found to comply with NEBS requirements as defined in Telcordia document SR 3580 Issue 2 January 2005 for NEBS Level 1 plus the amendments...

Page 24: ...he following methods Internet Visit the Zhone World Wide Web site at www Zhone com Be sure to register your warranty at www Zhone com warranty Telephone Call our automated system to receive current information by fax or to speak with a company representative Within the U S A and Canada call 877 Zhone 20 946 6320 Outside the U S A call 1 510 777 7000 If the equipment is causing harm to the telephon...

Page 25: ...gs are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products 7 Input power to this product must be provided by one of the following 1 a UL Listed CSA certified power source with a Class 2 or Limited Power Sour...

Page 26: ...omplete documentation for Zhone products is available at www Zhone com Select Service Support then select Documentation To order a paper copy of a Zhone document or to speak with a sales representative please call 877 Zhone 20 946 6320 ...

Page 27: ...27 Copyright 2007 Zhone Technologies Inc Printed in U S A ...

Page 28: ...28 ETH3 A2 ZN10 00 ...

Reviews: