118 of 168
MAINTENANCE AND USE MANUAL
EN
SATOVAC
Figure
1
Fig. 1: Position the machine correctly in the designated
area, observing the instructions in paragraphs 6.3 and
6.3.1.
Connect the lead to the mains power
socket: follow the instructions in section
6.4 carefully.
6.5
STARTING UP THE MACHINE
8
Figure
2
Fig. 2: Unscrew the bleed valve (8) on the upper part of
the vacuum pump.
4
3
Figure
3
Fig. 3: Pour the oil (supplied) until the spy-hole (4) is
reached. The oil level is correct when the spy-hole itself is
half-covered. Plug the intake valve (3) with an
appropriately sized piece of rubber (3) and run the pump
for a few minutes. This operation allows lubrication of
the internal parts of the pump.
Re-check the oil level: top up if necessary.
6.5.1 Introducing the oil
It is forbidden to tamper with the power lead and its plug. When replacing them
owing to damage and/or wear please contact an Authorised Service Centre.
A proper earth connection is compulsory. Should it temporarily be necessary
to use an extension lead the latter must comply with the standards in force
in the country of use.
Summary of Contents for SATOVAC 1
Page 1: ...satovac IT FR DE EN ES Vacuum machine...
Page 2: ......
Page 3: ...SATOVAC IT Pag 5 FR Pag 39 DE Pag 71 EN Pag 103 ES Pag 135...
Page 4: ...SATOVAC...
Page 165: ...SATOVAC...
Page 166: ...SATOVAC...
Page 167: ......
Page 168: ...XM1700000 15 09...