background image

15 of 36

MAINTENANCE AND USE MANUAL

DUNE

The 

DUNE 

has been designed to sandblast items used in the odontotechnics field. The 

DUNE 

unit is available as the 

DUNE Mod.2

 (two nozzles) and the 

DUNE Mod.3

 (three nozzles). The 

constant-pressure  tungsten  carbide  nozzles  are  available  in  various  sizes  so  that  the 

technician/operator can set up a sandblaster that meets his requirements perfectly. 

The following items are supplied as standard:

• n.2 nozzles ø 0.8 mm fitted on handpieces for 

DUNE Mod. 2

• n.3 nozzles ø 0.8 mm fitted on handpieces for 

DUNE Mod. 3

.

The tank cylinders feature an efficient constant vibration system, specially designed to keep the 

sand on the move at all times; this prevents the formation of lumps which might obstruct the 

nozzles. Furthermore, a new air pumping system inside the cylinders themselves ensures that 

all the sand exits the cylinders, thus eliminating the problem of continuous top-ups and breaking 

up any lumps of sand that have been caused by damp.

Because there is a not just one cylinder but a set of them the equipment features a switch for 

fast sandblasting change-overs: This makes work easier when different types of sand need to 

be used.  

DUNE

 

Mod. 2

 is built so that an optional third cylinder unit with pressure reducer, gauge and 

handpiece body can be added if desired.

CHAPTER 4:   TECHNICAL CHARACTERISTICS

4.1

TECHNICAL CHARACTERISTICS AND OPERATING START

4.2

TECHNICAL DATA

In addition to this Use and Maintenance Manual the 

DUNE

 comes complete with:

4.2.1

Standard accessories and accessories available on request

Technical data concerning the 

DUNE

:

 • Power supply 

 

V. 250/50-60 Hz single-phase

 • Absorbed power 

 

50 Watt max

 • Sands 

 

from 25 µm to 250 µm

 • Standard nozzle size 

 

0,8 mm

 • Internal neon light consumption 

 

9 Watt

 • Working pressure 

 

from 0,5 bar to 6 bar

 • Dimensions (H x L x P) 

 

41 cm x 48 cm x 62 cm

 • Weight 

 

35 Kg for Mod.2 / 44kg for Mod.3

 • Tank capacity 

 

500 cc

Nozzle ø 0,8 mm for sands from 60 µm to 110 µm (standard) 

XH9900110

Nozzle ø 1,3 mm for sands from 110 µm to 250 µm (accessory) 

XH9900120

Nozzle ø 0,5 mm for sands from 25 µm to 60 µm (accessory) 

XH9900100

Neon light 

XE1100040

Supplied kit 

XB0060670

Complete cylinder unit**  

 

XB0060650

C

omponents

 

 

o

rder

 C

ode

* Please quote the order code when ordering a spare part. You may order parts from your local Authorised Servicing Centre.

** Complete unit with tank, lid, pressure reducer, gauge and handpiece unit.

Summary of Contents for dune 2

Page 1: ...Maintenance and use manual XM0620000 Rev 12 07 SANDBLASTING MACHINE DUNE Mod DUNE 2 Cod C305613 Mod DUNE 3 Cod C305614...

Page 2: ......

Page 3: ...UK Pag 5...

Page 4: ......

Page 5: ...s Pag 14 3 3 Identification data CH 4 TECHNICAL CHARACTERISTICS Pag 15 4 1 Technical characteristics and operating start Pag 15 4 2 Technical Data Pag 15 4 2 1 Standard accessories and accessories ava...

Page 6: ...his manual may be modified without prior notice CH 8 MAINTENANCE Pag 25 8 1 Cleaning Pag 25 8 1 1 Cleaning the inside of the sandblasting equipment Pag 26 8 2 Changing the light bulb and or reactor Pa...

Page 7: ...must be available for consultation throughout the working life of the equipment even when the equipment is sold or finally dismantled It is recommended that you keep this manual constantly updated by...

Page 8: ...h must be observed at all times in order to protect both workers and equipment WARNING This symbol refers to safety standards which must be observed carefully in order to guarantee your safety other p...

Page 9: ...regards worker safety and or equipment performance 2 2 WARRANTY GENERAL INSTRUCTION Included in the Appendices to this Use and Maintenance Manual you will find the Warranty certificate and the ID Form...

Page 10: ...you are not distracted when using the equipment In the event of a malfunction follow the advice given in this manual if you have any doubts shut down the equipment and contact your Authorised Service...

Page 11: ...ack S p A cannot be held liable for any damage to persons or objects caused by incorrect maintenance carried out by unqualified personnel or main tenance work that does not comply with the instruction...

Page 12: ...t described in this manual is the DUNE sandblasting equipment designed to sandblast odontotechny products CHAPTER 3 DESCRIPTION OF THE EQUIPMENT 3 2 TABLE of the components DUNE Mod 3 24 23 25 27 22 3...

Page 13: ...ungsten carbide nozzle 18 Right hand passage ring 19 Right hand passage 20 Right cylinder vent valve 3 21 Right cylinder lid 3 22 Right cylinder 3 23 Pressure reducer 3 24 Main switch 25 Pressure gaug...

Page 14: ...ion of conformity When requesting spare parts information or assistance from the Zhermack S p A or your Authorised Servicing Centre always quote the data on the ID plate Should the ID plate deteriorat...

Page 15: ...ting change overs This makes work easier when different types of sand need to be used DUNE Mod 2 is built so that an optional third cylinder unit with pressure reducer gauge and handpiece body can be...

Page 16: ...oved any of the parts contained therein Should there be any damage or missing parts you must inform the Zhermack S p A Equipment Assistance Service or the Dealer where the equipment was purchased imme...

Page 17: ...Warranty null and void When shipping delivering the equipment to your Authorised Servicing Centre always enclose a copy of the purchase document and a copy of the properly compiled ID form If the uni...

Page 18: ...he quality of the work and proper maintenance This zone must not only be spacious enough to allow for optimum equipment operation but must also be well illuminated aired not dusty and not exposed to d...

Page 19: ...ell as efficacious overload indirect contact safety devices Connection is effected via the safety plug 16A in compliance with European standards at the end of the power lead this must be inserted in t...

Page 20: ...warranty null and void 6 6 PURPOSE OF THE EQUIPMENT IMPROPER USE AND FORBIDDEN USE The DUNE units have been designed and built for the sandblasting of odontotechny pro ducts The main reasons for which...

Page 21: ...following paragraphs correspond exactly to the numbering in Chapter 3 in the Equipment Description section In compliance with EC 89 392 international accident prevention standards these equipments ar...

Page 22: ...tem to be sandblasted inside the sandblasting chamber Close the hatch making sure it rests properly on the seal 14 3 4 1 21 22 33 Figure 5 Fig 5 Reposition the lids 3 21 and 1 on both cylinders 4 22 a...

Page 23: ...he sandblasting control is released thus optimising consumption This device also maintains the pressure inside the cylinder and so improves equipment response times when the sandblasting control is ac...

Page 24: ...rough the fitted nozzles it therefore follows that the residual risks are as follows being hit by jets of sand as a result of accidental opening of the glass hatch work carried out on the equipment in...

Page 25: ...s they could be hit by flying dust Before cleaning the equipment exterior always turn the main switch to OFF It is strictly forbidden to clean the equipment while it is connected to the mains power su...

Page 26: ...den to restart the equipment before such faults have been set right Equipment safety devices guards must never be removed except for repair and maintenance purposes Such items must be replaced as soon...

Page 27: ...y unauthorised personnel or non original spare parts are used the manufacturer is relieved of all responsibility If a maintenance task is required but is not described in this manual you must contact...

Page 28: ...sandblaster power lead is not properly inserted in the socket or is faulty bare damaged wiring etc 1 The feed duct is clogged 2 The nozzle is clogged 3 No sand inside the sandblasting chamber 4 The fe...

Page 29: ...29 of 36 MAINTENANCE AND USE MANUAL DUNE APPENDICES A 1 EC DECLARATION OF CONFORMITY A 2 WARRANTY CERTIFICATE AND IDENTIFICATION FORM A 4 NOTES A 3 MAINTENANCE AND REPAIR WORKSHEET...

Page 30: ...nd all related national legislation Electromagnetic compatibility CEE directive 89 336 amended and integrated by CEE directives 92 31 93 68 and 93 97 Low voltage CEE directive 73 23 amended and integr...

Page 31: ...Manufacturer authorised servicing centres or the Manufacturer The Warranty entitles the purchaser to free replacement of defective parts It does not entitle the purchaser to replacement of the entire...

Page 32: ...32 of 36 MAINTENANCE AND USE MANUAL DUNE A 3 MAINTENANCE AND REPAIR WORKSHEET Date Description of Work Signature...

Page 33: ...33 of 36 MAINTENANCE AND USE MANUAL DUNE A 4 NOTES...

Page 34: ...34 of 36 MAINTENANCE AND USE MANUAL DUNE...

Page 35: ......

Page 36: ...Zhermack S p A Via Bovazecchino 100 45021 Badia Polesine Rovigo Italy Tel 39 0425 597 611 www zhermack com w w w t ec nomedi a bi z...

Reviews: