Operating Instructions
2K2100 with STW
Taking into operation/Maintenance
4
Taking into operation
5
Maintenance
4.1
Initial inspection
5.1
Oil change
Check that the gearbox is correctly installed
before taking it into operation.
Oil change interval: every 5000 operating
hours
•
Mechanical fastening
•
Motor flange-mounting
ENVIRONMENTAL
HAZARDS!
!
Lubricants and cleaning products must
not be poured onto the ground, into
groundwater or down the drain.
•
Gearbox oil ports and connections
•
Oil supply/oil fill assured
• Obtain and comply with the safety
regulations relevant to these products
issued by your local environmental
authority.
•
Electrical connections
•
Ease of movement (can be turned by hand)
•
Breather vertical position
• Collect used oil in a suitably large
container.
• Dispose of used oil, clogged filters,
lubricants and cleaning products in
accordance with local environmental
protection regulations.
• Always follow the instructions issued
by the manufacturer when handling
lubricants and cleaning products.
Drain used oil at operating temperature into a
suitable container and remove from the pump
reservoir.
The drain ports differ depending on the
installation position and gearbox version (see
section 3.8.2).
Add new gearbox oil via the oil tank/reservoir.
After taking the pump into operation, check the
oil level continuously and top up if necessary.
The oil level itself is all-important. The oil
quantity in liters indicated on the model plate is a
reference value only.
Let the oil pump operate briefly after filling with
oil to remove any air and top up with oil again if
necessary.
29