Operating Instructions
2K2100 with STW
Initial installation
3.4.3
Open design with adapter ring for
2K2100, on request
The adapter ring allows adaptation to different
connection dimensions. A seal is required on the
motor output shaft.
The adapter ring (5) and drive hub (1) are
delivered loose. Clean the fitting surfaces of the
motor (3) and drive hub (1). Check the motor
shaft (2) for axial and radial runout as described in
section 3. Also lightly grease the motor shaft.
After cleaning the fitting surfaces, place the
adapter ring onto the motor housing. Then heat
the drive hub to approx 120 °C from the opening
and slide it onto the motor shaft (2) until it
reaches the stop.
Then check reference dimension "C" and change
using shims if necessary.
CAUTION
Risk of motor shaft damage if the hub is not
sufficiently heated.
Tighten the threaded pin (9) and secure it to
prevent it from turning, see section 3.5. The
factory-set sliding sleeve shift dimension "Y" can
be checked as described in section 3.5.
Dimension C
023652
17