background image

Summary of Contents for A10078-00

Page 1: ......

Page 2: ...Environment 6 2 6 Safety Symbols 6 3 Indication 7 3 1 LED Indication 7 3 2 LCD Indication 8 4 Installation 9 4 1 Location 9 4 2 Installation 9 5 Connection 11 5 1 Preparation 11 5 2 Connection Area 11...

Page 3: ...Fi 43 7 4 Browse PV plant 47 8 ZeverCloud website 51 8 1 Account Registration 51 8 2 Create a PV plant 52 8 3 Browse PV plant 53 8 4 Add a ZeverCom ZeverCom WiFi 54 8 5 PV plant Sharing 54 8 6 Configu...

Page 4: ...o confirm the latest revision 1 1 Scope of Application This manual applies to the ZeverCom ZeverCom WiFi firmware version 16B21 663R 16B21 658R and later versions 1 2 Target Reader This manual is inte...

Page 5: ...a and reports 2 1 Product Overview The ZeverCom ZeverCom WiFi collects the inverter s data and events in the PV plant When an Internet connection is present the ZeverCom ZeverCom WiFi will upload the...

Page 6: ...e following inverters and function Model Active power limit 0 export DRM Eversol TL1000 TL3000 Yes No No Evershine TL3680 TL5000 Yes No No Zeverlution 1000 3000S Yes Yes Yes Zeverlution 3680 5000 Yes...

Page 7: ...he ZeverCom ZeverCom WiFi operational ambient temperature is 10 C to 60 C Do not allow the ZeverCom ZeverCom WiFi to become damp or wet during use Sudden disconnection of power to the ZeverCom ZeverCo...

Page 8: ...rCom ZeverCom WiFi is supplied with voltage Off ZeverCom ZeverCom WiFi is not supplied with voltage Glowing yellow A WiFi connection has been established between the ZeverCom WiFi and WLAN router Flas...

Page 9: ...he ZeverCloud Connected ZeverCloud ZeverCom ZeverCom WiFi is connected to the ZeverCloud Total INV 05 Online INV 03 Total INV 05 is the total number of inverters connected to the ZeverCom ZeverCom WiF...

Page 10: ...to 1000m If the ZeverCom WiFi has the WiFi option the antenna should be assembled as per Fig 4 1 Please ensure that the signal strength between the WLAN router and the ZeverCom WiFi is strong enough...

Page 11: ...have accumulated from the drill holes Step5 Insert the screw anchors into the drill holes using a rubber mallet Step6 Screw in the screws until they protrude by 5mm Fig 4 3 Screw in the screws Step7...

Page 12: ...cable line 1000m Remember to connect the Ethernet cable to the Ethernet port RJ45 LAN connectors and not to the RS485 port 5 2 Connection Area The ZeverCom ZeverCom WiFi collects inverter s data and e...

Page 13: ...power outlet and check that the power LED light turns on as shown in Fig 3 1 LED indicator panel If a separate power supply unit is used it must satisfy the following requirements 1 EMC directive and...

Page 14: ...own in Table 5 3 Table 5 3 RJ45 RS485 pin assignment Pin Signal description 1 RX 2 RX 3 TX 4 GND 5 GND 6 TX 7 7V 8 7V 1 The RS485 port between the ZeverCom ZeverCom WiFi and the inverter Item C in Fig...

Page 15: ...s wiring details The ZeverCom ZeverCom WiFi supports the following EASTRON energy meter model SDM630DC Modbus SDM630CT Modbus SDM120 Modbus SDM220 Modbus SDM230 Modbus Fig 5 4 System Connection with E...

Page 16: ...nment is shown in Table 5 4 Table 5 4 Meter port pin assignment Pin Signal description 1 RS485 A 2 RS485 B For the information on how to set the power limitation of PV system please refer to the Activ...

Page 17: ...the ZeverCloud Both of these two ports must be opened otherwise the ZeverCom ZeverCom WiFi cannot connect to the ZeverCloud and upload data Internet LAN ZeverCom Inverter_1 Inverter_2 Inverter_5 RS48...

Page 18: ...must be activated If the IP address of the ZeverCom ZeverCom WiFi is different from the network segment assigned by the router Trouble shooting 1 Make sure the DHCP service of router has been activate...

Page 19: ...e taken Step1 Power on the ZeverCom WiFi and open the mobile device or laptop s WLAN page to find the ZeverCom WiFi s wireless access point The new access point of the ZeverCom WiFi s SSID called ZEVE...

Page 20: ...Step4 Enter the password of the wireless local network that you wish to connect to Do not enter the password of the router Step5 After approximately three minutes the WiFi of the ZeverCom WiFi will c...

Page 21: ...M 3 Do not consume at more than 75 of rated power ANDSource reactive power if capable DRM 4 Increase power consumption subject to constraints from other active DRMs DRM 5 Do not generate power DRM 6 D...

Page 22: ...Connection 21 Fig 5 13 DRMs RJ45 Connection Circuit The DRMs function parameters setting please refer to 6 4 1...

Page 23: ...cting via Ethernet Input the IP address of the ZeverCom ZeverCom WiFi shown on the LCD display in the browser s address bar For example if the IP address shown on the ZeverCom ZeverCom WiFi is 192 168...

Page 24: ...Com ZeverCom WiFi equipment It also shows the state of the connected inverters which is shown in Fig 6 2 If the inverter is working normally it shows a green icon otherwise the red icon will be shown...

Page 25: ...Com WiFi For example the Multi Function Switch and output Power limit function can be configured In addition the ZeverCom ZeverCom WiFis firmware can be upgraded from this webpage 6 4 1Power Managemen...

Page 26: ...talled Inverter AC Capacity In this method the AC output of the PV system will not exceed a set percentage of the installed inverter AC capacity For example if a 20 limitation on a 33 kWp PV system co...

Page 27: ...the set value For example if 0 kWac export limit has been set in limit output power based on the energy meter reading then a 33 kWp PV system connected to Zeverlution Pro 33K 33 kWac inverter will re...

Page 28: ...The PV system will automatically to regulate inverter s output power to make sure inverter s output power won t exceed the load power in this case no PV power can feed into the grid Fig 6 7 Power flow...

Page 29: ...n a The sum of the rated power of all inverters in the PV plant Wac c It expect power reading of the energy meter d The energy meter model Based on the AS DRMs Safety The output power is be decided by...

Page 30: ...ctive power feed in at over frequency Limit c Active power feed in at over volt Limit The Fig 6 11 Set active power feed in at over volt limit d Reactive Power Limit There are four modes of reactive p...

Page 31: ...ccording to this curve as shown in Fig 6 14 Fig 6 13 Cos phi variable mode 0 95 0 4 0 6 0 8 P Pn Cos 1 0 2 0 95 Leading Lagging Fig 6 14 Cos phi variable Cure Q fix mode In this mode the ZeverCom Zeve...

Page 32: ...rding to this curve as shown in Fig 6 17 Fig 6 16 Q variable mode 0 50 1 00 1 04 1 08 U Un Q 1 0 96 0 50 Leading Lagging 1 12 Fig 6 17 Q variable Cure To cancel the output power limit function untick...

Page 33: ...Fig 6 18 Safety Parameters 6 4 3 Updating Firmware The firmware of the ZeverCom ZeverCom WiFi can also be updated It can also update the inverter s firmware Enter the Advanced page and click the choo...

Page 34: ...he OK button at the Restart section to restart the device Fig 6 20 Restart ZeverCom ZeverCom WiFi 6 4 5 Restore to Factory Enter the Advanced page of the ZeverCom ZeverCom WiFi and click the OK button...

Page 35: ...ss This page shows the list of wireless Networks that ZeverCom ZeverCom WiFi can connect to If you want to change the connected WiFi network please refer to section5 7 Fig 6 22 Wireless Network The wi...

Page 36: ...ault password is zeversolar To ensure highest security of your system please change the default password zeversolar and keep the new password confidential If you do not change the password you expose...

Page 37: ...their PV plants and inverters remotely via a smart mobile device You can visit and download ZeverCloud APP via the following website on your mobile phone Android https www zeversolar com products pro...

Page 38: ...or via the ZeverCloud website Monitoring can then be performed after the user has registered and created a PV plant Step 1 Open ZeverCloud APP which has been downloaded and installed on your device a...

Page 39: ...on marked with a 1 in Fig 7 3 to enter the login page as shown in Fig 7 4 Fig 7 4 Login Step 3 Click the button marked with a 1 in Fig 7 4 click Register to enter the registration page input the avail...

Page 40: ...tter A a Z z and numbers 0 9 can be accepted Fig 7 5 Registration Step 4 After the registration has been completed ZeverCloud will send an activation e mail Activate your ZeverCloud account according...

Page 41: ...arked with a 1 in Fig 7 3 to enter the login page as shown in Fig 7 4 Step 3 Input your user name and password in the area as shown in Fig 7 4 to login to ZeverCloud APP If the login is successful you...

Page 42: ...nt button in the navigation bar at the bottom of the screen as shown in Fig 7 6 to enter the PV plant create page as shown in Fig 7 7 Follow the prompts on the page to establish a PV plant input Zever...

Page 43: ...al number and registry number of the monitoring device can be entered by clicking the scan button marked with a 1 as shown below to scan the QR code on the label of monitoring device ZeverCom ZeverCom...

Page 44: ...r and registry number of the ZeverCom ZeverCom WiFi or or to scan a QR code which contains these two pieces of information Thisinformation can be found on the ZeverCom ZeverComWiFi label 7 3 Connect M...

Page 45: ...ZeverCloud APP 44 Fig 7 8 Wireless network list Click SSID of ZeverCom type in password as shown in fig default password zeversolar...

Page 46: ...ZeverCloud APP 45 Fig 7 9 Enter the password Smartphone connected to ZeverCom successfully as shown in fig 7 10...

Page 47: ...r at bottom as shown in Fig 7 7 to enter the WiFi configuration page as shown in Fig 7 11 Here you can modify the WIFI password of the monitoring devices as well as modify the account name and passwor...

Page 48: ...ally connected your terminal mobile device to the WiFi of the monitoring device 7 4 Browse PV plant You can enter any PV plant by clicking the plant list as shown in Fig 7 6 This allows you to view th...

Page 49: ...ome E Today E Month E Total as well as power generation charts like current day real time power current month s daily power current year s monthly power annual summarized power generation as shown in...

Page 50: ...oud APP 49 7 4 2 Charts This menu provides detailed curve graphs i e DC input voltage Vpv DC input current Ipv and AC output power Pac of the PV plant and every inverter as shown in Fig 7 14 Fig 7 14...

Page 51: ...evices This menu provides the status of monitoring devices as well as other contents such as relevant parameter error information of inverters that are connected to this monitoring device as shown in...

Page 52: ...apter 7 7 to download ZeverCloud APP To monitor the PV plant and inverter with ZeverCloud the ZeverCom ZeverCom WiFi and Internet must be functioning normally 8 1 Account Registration Users who use Ze...

Page 53: ...u may have input an email address which is different from the one you used for registration Please confirm if the email was sent to another email address Please reregister if you entered an unknown em...

Page 54: ...he ZeverCom ZeverCom WiFi This information can be found on the ZeverCom ZeverCom WiFi label 8 3 Browse PV plant You can enter any PV plant by clicking the plant list This allows you to view the power...

Page 55: ...detailed information of each inverter s work state 8 4 Add a ZeverCom ZeverCom WiFi A ZeverCom ZeverCom WiFi can be added to a PV plant as follows Step1 Login to ZeverCloud and enter Configuration Dev...

Page 56: ...authorities of the shared users 8 6 Configuration Report ZeverCloud can email you the daily and monthly operation state of the PV plant including the amount of generated energy yield CO2 emission redu...

Page 57: ...ZeverCloud website 56 Fig 8 7 Activate the configuration report Step3 After the above steps click the Save button to save your settings then click Test button to send to an email immediately...

Page 58: ...Red light does not flash after green light flashed Inverter did not send data to ZeverCom ZeverCo m WiFi Check that the connection between inverter and ZeverCom ZeverCom WiFi is not damaged or discon...

Page 59: ...al number Please contact our after sales service personnel INV SN Space The serial number of the inverter connected to the ZeverCom ZeverCom WiFi is blank Please contact our after sales service person...

Page 60: ...the number of inverters connected to the ZeverCom ZeverCom WiFi Refer to section 6 2 Q2 How can I confirm whether the ZeverCom ZeverCom WiFi is successfully connected to ZeverCloud Check the LCD on t...

Page 61: ...x 5 WiFi communication 2 4GHz 802 11 b g n WEP WPA WPA2 PSK Interface Ethernet 10 100 Mbit s RJ45 for Router 10 100 Mbit s RJ45 for Router RS485 4 wires 4 wires Meter RS485 2 wires 2 wires Max communi...

Page 62: ...he recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that...

Page 63: ...roducts please contact SMA service SMA New Energy Technology Jiangsu Co Ltd Tel 86 512 6937 0998 Fax 86 512 6937 3159 E mail service china sma solar com Factory add No 588 Gangxing Road Yangzhong Jian...

Page 64: ......

Reviews: