Programming
60
Guard Tone Duration 0 to 900
milliseconds
Sets the duration of the high level Guard Tone. Type in a value and
press ENTER.
Function tones sent
When selected
Upon transmit
Sets whether function control tones are sent immediately when their
key is pressed, or only after the transmit key is pressed.
Function Tone
Duration
0 to 250
milliseconds
Sets the duration of the function tones. Type in a value and press
ENTER.
Function Tone
Removal
Yes, No
Sets whether this deskset will mute its speaker while function tones
are being sent by parallel desksets. If set to Yes, the receive audio
will be slightly delayed.
Immediate Talk
Yes, No
Sets whether or not this deskset will buffer the operator’s voice audio
while the function tones are being sent. If set to Yes, the transmit
audio will be delayed slightly.
Additional Talk Delay 0, 100, 200, 300,
400 milliseconds
In order to use the “Immediate Talk” feature properly, you may
require additional audio delay to give the mobiles time to unsquelch.
This additional delay time is set using this menu. The time is shown
in milliseconds. If the menu item “Immediate Talk” is set to “No”,
then this delay timer will not be used. Use the Spacebar to step
through settings.
Four Wire Option
Yes, No
Sets whether or not this deskset is capable of full-duplex audio. It
should always be set to “No” for 2-wire installations. In the Model
284 this function appears in the Line parameters menu.
AGC Dynamic Range
Lo
Hi
If leased lines are not used the dynamic range of the AGC circuit can
be reduced to improve the level of background noise picked up by the
deskset. Set low-loss lines to low and high-loss lines to high. In the
Model 284 this function appears in the Line parameters menu.
Parallel Status
Yes, No
Sets whether or not this deskset updates its display when parallel
desksets change the channel of the base station. If set to No, this
deskset will continue to display the last channel selected from its own
front panel.
Supervisors Unit
Yes, No
When set to Yes, it makes this deskset a Supervisor unit, and it will
be immune to the Privacy function when used by other desksets in
the system. This function should not be confused with the Supervisor
output, which is used to disconnect other remotes from the system.
Unselect Audio
Off, Handset/Spkr,
Line 4
You may listen to audio that is received on the lines that are not
selected. Use this setting to control the selection. The audio may be
routed out the Line 4 interface to a speaker that you connect, or heard
on the handset and built in speaker. It may also be turned off
completely. Use the Spacebar to step through the available settings.
Unselect Mute During
Tx
Yes, No
Enable this function to automatically mute the unselect audio while
you are transmitting. If you do not have the unselect audio enabled,
this function will not make a difference. Use the Spacebar to toggle
this setting.
Off Hook Speaker
Enable
Yes, No
To keep the speaker enabled when the handset is off hook, set this
function to “Yes”, otherwise leave it set to “No”. The receive audio
will be present in the ear piece of the handset in both cases. Use the
Spacebar to toggle this setting.
Parameter
Range
Description