MULTI-LOOP PANEL

 

 
 
 
 
 
 

 

 

 

Installation Manual 

Summary of Contents for SMARTCONNECT SMART6

Page 1: ...GLT 261 7 3 Doc GLT 261 7 1 Issue W I P Date 25 08 2018 Doc GLT 261 7 10 Issue 001 Date 14 08 2020 MULTI LOOP PANEL Installation Manual...

Page 2: ...ble Grounding 13 Mains Wiring 13 Battery Wiring 15 Assembling the panel 18 Initial Power Up 19 Module Installation 19 TRM RJ45 Port Address Designation 20 Securing the modules 20 Before Powering the P...

Page 3: ...ifications 36 Compatible Loop Card Devices 36 Power Supply 37 PSU Specifications 37 PSU Fuses 38 Power Supply Status Indications 38 Power Supply Signals 38 Panel Printer 39 Loading Replacing the Print...

Page 4: ...l to the device or zone The 32 bit microcontroller MCU at the heart of Smart Connect Multi loop rapidly processes logical decisions based on the status of the smoke detection and other initiating devi...

Page 5: ...Engineer Password Default 9999 and press Menu Access Icon Configure loops Assign zones Assign Text to each point Modify Alarm Operation Programming Configure network if fitted System Diagnostics LED...

Page 6: ...ired conventional inputs and outputs and addressable inputs and outputs may be grouped together to form logical zones Wiring Styles Loop Circuits have a redundant pathway powered from both sides of th...

Page 7: ...a 400W 15A PSU Space for 2 x 14Ah batteries SMART10 64 W 500mm x H 600mm Space for up to 10 small modules Equipped with 64 zone LED expansion Supplied with a 400W 15A PSU Space for 2 x 38Ah batteries...

Page 8: ...HF MKII AHF CS90 ZAI MI ZAIO MI ZAZM MI ZAIO 230 ZASC MI MKII SSB MKII AXT MKII AXTB ZRAP ZRAPB All are EN54 approved SCM ACM Alarm Circuit Module The plug in alarm circuit module provides power for a...

Page 9: ...ies etc Input Voltage 23 7VDC Nominal Wiring Class 6 x Class B Quiescent Current 30V 39 3mA Input Max Impedance 10 Input End of Line 4K7 Alarm Triggering Resistor 1K SCM ZMM Zone Monitor A zone monito...

Page 10: ...RT 10 665mm 535mm 505mm 200mm 170mm 635mm 26 8 4 2 x 38Ah SMART 26 665mm 975mm 945mm 200mm 170mm 635mm 64 28 20 2 x 38Ah Panel Construction Details All components are manufactured from Zintec Large an...

Page 11: ...panel must be in a clean dry position which is not subject to excessive shock or vibration and at least 2 meters away from pager systems or any other radio transmitting equipment The operating tempera...

Page 12: ...Smart Connect Multi loop Installation Manual www zetaalarmsystems com 12 Fig 2 Fig 3...

Page 13: ...l damage Also the power supply and termination board should be removed and stored in a safe place This would also help while fixing the back box to the wall Cable Grounding The panel is provided earth...

Page 14: ...ns Earth cable is connected to the PSU s Earth terminal The incoming mains cable should be kept separate from the loop card cables to help minimise mains interference It is advisable to apply power to...

Page 15: ...ration 0 25A2s 230Vac Cold Start 3 15A 230 V AC Battery Wiring The SMART Connect Multi loop panel uses two 12 Volt batteries wired in series to give a 24 Volt back up supply The ve of one battery is c...

Page 16: ...harger Current Max Battery Size Fuse Installed SMART6 29 5V DC 27 6V DC 400W 1 1A 2 x 12V 14 Ah 5A SMART10 29 5V DC 27 6V DC 400W 2 2A 2 x 12V 38 Ah 8A SMART26 29 5V DC 27 6V DC 400W 2 2A 2 x 12V 38 A...

Page 17: ...Smart Connect Multi loop Installation Manual www zetaalarmsystems com 17...

Page 18: ...ed and connect to the panel s motherboard with a small RJ45 cable supplied with the module The Base panel is available in 3 sizes SMART6 SMART10 SMART26 The above diagrams show the port addresses for...

Page 19: ...now be turned off and the modules can be fitted Module Installation The Smart Multi loop panel uses the expansion port number to reference modules It is recommended that any Loop Card modules are fitt...

Page 20: ...e first module and after the last module on each rail Before Powering the Panel On 1 To prevent the risk of a spark do not connect the batteries Only connect the batteries after powering on the system...

Page 21: ...ected modules are fitted and that all module cables are correctly inserted Note that the panel will need at least one module fitted to run The panel has detected a new module added to a port that was...

Page 22: ...e EARTH Green NEG POS NEG POS BLACK RED BATTERY CABLE OBSERVE POLARITY RED BLACK SCM LCM S CM A CM SCM ZMM SCM MIM SCM RM SCM NM SCM PM A A B B NAC1 A A A A C C C C C C C C C C C C C C C ZM1 ZM2 ZM3 Z...

Page 23: ...tems com 23 SCM ACM Field Wiring Connections Typical Wiring Diagram Class B Zeta Conventional Sounders Typical Wiring Diagram Class B Bell Devices NOTE When an ACM is configured as a bell output the 2...

Page 24: ...e Regulated 24V DC Power limited Supervised Maximum Alarm Circuit Current 2 x 500mA Maximum Aux 24V Current 2 x 400mA Maximum RMS current for a single sounder device 350mA Maximum Line Impedance 3 6 t...

Page 25: ...output Please refer to the device manuals to calculate the maximum number allowed on each alarm circuit SCM MIM Field Wiring Connections Wiring Recommendations for Input Circuits SCM MIM Wire Gauge AW...

Page 26: ...Form C Switching Capacity 5 A 30VDC resistive 5 A 250VAC general use Circuit Type Power limited Not Supervised Modes Common alarm Common fault Common tech alarm or Programmable Recommended cable sizes...

Page 27: ...iring Class 6 x Class B circuits Recommended cable sizes 22 AWG to 14 AWG 0 3mm2 to 2 5mm2 End of Line Resistor 4K7 Alarm Trigger Resistor 1K Compatible Devices MKII OP MKII HR MKII HF MKII HF CS90 MK...

Page 28: ...allation Manual www zetaalarmsystems com 28 SCM NM Field Wiring Connections Ring Topology Bus Topology NOTE It is recommended to install the network in a ring topology for protection against open circ...

Page 29: ...iring SCM NM The SMART Connect Multi loop network can support up to 64 panels SCM NM Specifications Network Module SCM NM Maximum Network Size 64 Nodes Maximum Distance Between Nodes 1KM with screened...

Page 30: ...r 2 or more detection zones short circuit isolators or devices with built in short circuit isolators such as interfaces should be fitted to the zone boundaries to prevent a single short circuit affect...

Page 31: ...ngs PVC plastic foam and all similar materials which produce small visible particles 0 5 to 10 m MKII AHR MKII AHFand MKII AHF CS90 MKII AHR MKII AHF and MKII AHF CS90 The Fyreye MKII Rate of Rise hea...

Page 32: ...MKII AHF CS90 MKII AHR and MKII AOH detector series heads The series includes MKII CB which is a 4 inch standard base and MKII CB D which is 4 inch deep base MKII CB MKII CB D are supplied with 5 ter...

Page 33: ...ondition Typical output triggering includes controlling lift operation during an alarm starting fire pump stopping ventilation fans etc ZAIO MI typical wiring diagram E g connecting to a door magnet Z...

Page 34: ...rs have been activated or extinguisher level monitoring in Gas Extinguishing systems etc Module is provided with a loop short circuit isolator and with a voltage free single pole change over mains rat...

Page 35: ...or a clean first fix The AXTB beacon has a coverage pattern of W 3 1 9 1 MKII AXT MKII AXTB typical wiring diagram E g Loop wiring ZRAP ZRAPB ZRAPB R pictured ZRAP ZRAPB The Raptor addressable sounder...

Page 36: ...Smoke Heat A1R Detector With Built In Isolator MKII AOHI MKII Addressable Fixed Heat Only A2S Detector With Built In Isolator MKII AHFI MKII Addressable Fixed Heat Only CS Detector With Built In Isola...

Page 37: ...ltage 120 230 VAC 120 230 VAC 120 230 VAC Power Supply Rating 400 Watts 400 Watts 400 Watts DC Output Voltage 30 VDC 30 VDC 30 VDC Maximum Output Current 11 1 Amp 11 1 Amp 11 1 Amp Battery Voltage 27...

Page 38: ...NC C in normal operating condition When there is a fault condition on the mains power continuity is switched to NO C Relay is normally energized and fail safe as the relay will change over in the eve...

Page 39: ...cification PLUS2 Paper Type Thermal Paper Roll Paper Width 57mm Roll Diameter 50mm Roll Length 30m See note Paper Weight 55 to 70gsm To change the printer roll proceed as follows Every time the paper...

Page 40: ...Reception errors Parity frame error overrun error ON Flash x 6 Green Command is not recognised ON Flash x 7 Green Command reception has timed out Printer Maintenance The regular cleaning of the panel...

Page 41: ...Output B Auxiliary Power 29V 1A 29V 1A 29V 1A Output C Control Panel Power 29V 7 5A 29V 7 5A 29V 7 5A Output D Control Panel Power 29V 7 5A 29V 7 5A 29V 7 5A Display LCD Display 4 3 Resistive touch sc...

Page 42: ...c Other Functions outside EN54 USB port For PC configuration and software upgrading RS485 Network Repeater connection TCP IP Ethernet connection Remote access Programmable Cause Effect on Outputs Phas...

Page 43: ...S C Isolator 3 5 13 2 ZAIO 230 MKII Addressable Mains switching Input Output Module 1 5 4 6 SMM B Special Mini Modules White Beam Detector 1 1 12 MKII SSB MKII Sandwich Sounder No Address Required 0...

Page 44: ...F ON ON 88 ON ON ON OFF OFF ON OFF ON 3 OFF OFF ON ON ON ON ON ON 46 ON OFF OFF OFF ON OFF ON ON 89 OFF ON ON OFF OFF ON OFF ON 4 ON ON OFF ON ON ON ON ON 47 OFF OFF OFF OFF ON OFF ON ON 90 ON OFF ON...

Page 45: ...F ON OFF ON OFF ON OFF ON 128 ON ON ON ON ON ON ON OFF 171 OFF OFF ON OFF ON OFF ON OFF 214 ON OFF OFF ON OFF ON OFF OFF 129 OFF ON ON ON ON ON ON OFF 172 ON ON OFF OFF ON OFF ON OFF 215 OFF OFF OFF O...

Page 46: ...ON OFF 208 ON ON ON ON OFF ON OFF OFF 251 N O T U S E D 166 ON OFF OFF ON ON OFF ON OFF 209 OFF ON ON ON OFF ON OFF OFF 252 N O T U S E D 167 OFF OFF OFF ON ON OFF ON OFF 210 ON OFF ON ON OFF ON OFF...

Page 47: ...m voltage Multi Relay Module RM NO N A Isolated from system voltage Multi Relay Module RM CM N A Isolated from system voltage Multi Relay Module RM NC N A Isolated from system voltage In quiescent con...

Page 48: ...m 48 Installation Manual Modification History Issue Date Changes 001 19 03 2020 Added manual modification history table Impedance values changed to 10K Removed non LED MMP10 MMP26 version Changed PSU...