18 • Electrical/Control
ELECTRICAL/CONTROL
7.0 .05
1.5 .05
RCPT NEUTRAL
3
BLK/R-P-O
A/S LINE
5
1
2
WIRE NO.
11 6
9
8 10
7
4
3
65-1979-011 REV A
WIRE NO.
COLOR
PURPOSE
7
ORG
LIGHTS LINE
DEFROST HEATER
A/S NEUTRAL
LIGHTS NEUTRAL
RCPT LINE
CHASSIS GND
FANS LINE
DEFROST HEATER
RED/GRY
WHT/YEL
WHT/ORG
WHT/PUR
GRN
WHT/R-P-O
BLK/YEL
RED/PUR
BLK/GRY
2
11
10
9
8
6
5
4
1
COLOR
PURPOSE
65-1979-011 SHOWN
FANS NEUTRAL
7.0 .05
1.5 .05
ZERO ZONE WORKMANSHIP STANDARDS SHALL APPLY PER
ES-08-1007
ASME Y14.41-2012 & ASME Y14.5-2009 SHALL APPLY AS REQUIRED
ALL DIMENSIONS IN INCH UNLESS OTHERWISE SPECIFIED
SIGNIFICANT DIMENSIONS DENOTED BY X.XX
OR X.XXX AND MUST MEET Cpk ≥ 1.33.
CRITICAL DIMENSIONS DENOTED BY X.XX
OR X.XXX
AND MUST MEET Cpk ≥ 1.66.
CAD DRAWING
NO MANUAL REVISIONS
COPYRIGHT INFORMATION
THIS DRAWING AND THE INFORMATION CONTAINED WITHIN,
IS THE SOLE PROPERTY OF ZERO ZONE, INC. ANY USE OF
THIS DOCUMENT OR DISCLOSURE OF ITS CONTENTS; BY
REPRODUCTION OR OTHER MEANS, WITHOUT THE WRITTEN
CONSENT OF ZERO ZONE, INC. IS STRICTLY PROHIBITED.
NONE
TYPE II PAPER LABEL (PER ES-08-1007-154)
FINISH:
MATERIAL:
NOT TO SCALE
SCALE:
9/15/2021
01
1 OF 4
65-1979
LABEL UPPER ELECTRICAL BOX
HYB CONNECTOR
SHEET:
DATE:
REVISION
ZERO ZONE, INC.
110 NORTH OAKRIDGE DRIVE
NORTH PRAIRIE, WISCONSIN
USA 53153
DRAWING No:
DESCRIPTION:
REVISION INFORMATION
01
NEW CREATION
1819
9/30/2021
OP
No. REVISION DESCRIPTION
CO No.
DATE
BY
SHEET SIZE
A
TOLERANCES SHALL APPLY
UNLESS OTHERWISE SPECIFIED
.X = ± .1 .XX = ± .02
.XXX = ± .005 ANGLES, ± 1º
A
A
B
B
2
2
1
1
1.5 .05
4.0 .05
14
13
16
15
12
WIRE NO.
PURPOSE
14
15
16
12
GRN
BLK
RED
WHT
CNDU COMMAND
CHASSIS GND
AC NEUTRAL
AC LINE 2
65-1979-012 REV A
BLU
13
AC LINE 1
65-1979-012 SHOWN
COLOR
ZERO ZONE WORKMANSHIP STANDARDS SHALL APPLY PER
ES-08-1007
ASME Y14.41-2012 & ASME Y14.5-2009 SHALL APPLY AS REQUIRED
ALL DIMENSIONS IN INCH UNLESS OTHERWISE SPECIFIED
SIGNIFICANT DIMENSIONS DENOTED BY X.XX
OR X.XXX AND MUST MEET Cpk ≥ 1.33.
CRITICAL DIMENSIONS DENOTED BY X.XX
OR X.XXX
AND MUST MEET Cpk ≥ 1.66.
CAD DRAWING
NO MANUAL REVISIONS
COPYRIGHT INFORMATION
THIS DRAWING AND THE INFORMATION CONTAINED WITHIN,
IS THE SOLE PROPERTY OF ZERO ZONE, INC. ANY USE OF
THIS DOCUMENT OR DISCLOSURE OF ITS CONTENTS; BY
REPRODUCTION OR OTHER MEANS, WITHOUT THE WRITTEN
CONSENT OF ZERO ZONE, INC. IS STRICTLY PROHIBITED.
NONE
TYPE II PAPER LABEL (PER ES-08-1007-154)
FINISH:
MATERIAL:
NOT TO SCALE
SCALE:
9/15/2021
01
2 OF 4
65-1979
LABEL UPPER ELECTRICAL BOX
HYB CONNECTOR
SHEET:
DATE:
REVISION
ZERO ZONE, INC.
110 NORTH OAKRIDGE DRIVE
NORTH PRAIRIE, WISCONSIN
USA 53153
DRAWING No:
DESCRIPTION:
REVISION INFORMATION
01
NEW CREATION
1819
9/30/2021
OP
No. REVISION DESCRIPTION
CO No.
DATE
BY
SHEET SIZE
A
TOLERANCES SHALL APPLY
UNLESS OTHERWISE SPECIFIED
.X = ± .1 .XX = ± .02
.XXX = ± .005 ANGLES, ± 1º
A
A
B
B
2
2
1
1
4.0 .05
1.5 .05
14
11
9
12
10
65-1979-021 REV A
LIGHTS NEUTRAL
FANS NEUTRAL
CHASSIS GND
FANS LINE
LIGHTS LINE
GRN
WHT/YEL
WHT/ORG
BLK/YEL
ORG
14
12
11
10
9
PURPOSE
COLOR
WIRE NO.
65-1979-021 SHOWN
ZERO ZONE WORKMANSHIP STANDARDS SHALL APPLY PER
ES-08-1007
ASME Y14.41-2012 & ASME Y14.5-2009 SHALL APPLY AS REQUIRED
ALL DIMENSIONS IN INCH UNLESS OTHERWISE SPECIFIED
SIGNIFICANT DIMENSIONS DENOTED BY X.XX
OR X.XXX AND MUST MEET Cpk ≥ 1.33.
CRITICAL DIMENSIONS DENOTED BY X.XX
OR X.XXX
AND MUST MEET Cpk ≥ 1.66.
CAD DRAWING
NO MANUAL REVISIONS
COPYRIGHT INFORMATION
THIS DRAWING AND THE INFORMATION CONTAINED WITHIN,
IS THE SOLE PROPERTY OF ZERO ZONE, INC. ANY USE OF
THIS DOCUMENT OR DISCLOSURE OF ITS CONTENTS; BY
REPRODUCTION OR OTHER MEANS, WITHOUT THE WRITTEN
CONSENT OF ZERO ZONE, INC. IS STRICTLY PROHIBITED.
NONE
TYPE II PAPER LABEL (PER ES-08-1007-154)
FINISH:
MATERIAL:
NOT TO SCALE
SCALE:
9/15/2021
01
3 OF 4
65-1979
LABEL UPPER ELECTRICAL BOX
HYB CONNECTOR
SHEET:
DATE:
REVISION
ZERO ZONE, INC.
110 NORTH OAKRIDGE DRIVE
NORTH PRAIRIE, WISCONSIN
USA 53153
DRAWING No:
DESCRIPTION:
REVISION INFORMATION
01
NEW CREATION
1819
9/30/2021
OP
No. REVISION DESCRIPTION
CO No.
DATE
BY
SHEET SIZE
A
TOLERANCES SHALL APPLY
UNLESS OTHERWISE SPECIFIED
.X = ± .1 .XX = ± .02
.XXX = ± .005 ANGLES, ± 1º
A
A
B
B
2
2
1
1
1.5 .05
4.0 .05
3
WIRE NO. COLOR
PURPOSE
1
2
3
4
BLK
WHT
GRN
BLU
AC NEUTRAL
65-1979-022 REV A
2
1
4
AC LINE
CHASSIS GND
CNDU COMMAND
65-1979-022 SHOWN
ZERO ZONE WORKMANSHIP STANDARDS SHALL APPLY PER
ES-08-1007
ASME Y14.41-2012 & ASME Y14.5-2009 SHALL APPLY AS REQUIRED
ALL DIMENSIONS IN INCH UNLESS OTHERWISE SPECIFIED
SIGNIFICANT DIMENSIONS DENOTED BY X.XX
OR X.XXX AND MUST MEET Cpk ≥ 1.33.
CRITICAL DIMENSIONS DENOTED BY X.XX
OR X.XXX
AND MUST MEET Cpk ≥ 1.66.
CAD DRAWING
NO MANUAL REVISIONS
COPYRIGHT INFORMATION
THIS DRAWING AND THE INFORMATION CONTAINED WITHIN,
IS THE SOLE PROPERTY OF ZERO ZONE, INC. ANY USE OF
THIS DOCUMENT OR DISCLOSURE OF ITS CONTENTS; BY
REPRODUCTION OR OTHER MEANS, WITHOUT THE WRITTEN
CONSENT OF ZERO ZONE, INC. IS STRICTLY PROHIBITED.
NONE
TYPE II PAPER LABEL (PER ES-08-1007-154)
FINISH:
MATERIAL:
NOT TO SCALE
SCALE:
9/15/2021
01
4 OF 4
65-1979
LABEL UPPER ELECTRICAL BOX
HYB CONNECTOR
SHEET:
DATE:
REVISION
ZERO ZONE, INC.
110 NORTH OAKRIDGE DRIVE
NORTH PRAIRIE, WISCONSIN
USA 53153
DRAWING No:
DESCRIPTION:
REVISION INFORMATION
01
NEW CREATION
1819
9/30/2021
OP
No. REVISION DESCRIPTION
CO No.
DATE
BY
SHEET SIZE
A
TOLERANCES SHALL APPLY
UNLESS OTHERWISE SPECIFIED
.X = ± .1 .XX = ± .02
.XXX = ± .005 ANGLES, ± 1º
A
A
B
B
2
2
1
1
Case Electrical Connections - Pinout Locations
Refer to these figures to identify the function of each pin in the connectors. Only applies to Highlight
™
and Reveal
™
.
COOLER: CONN-1 FROM ELECTRICAL BOX TO CASE
COOLER: CONN-2 FROM ELECTRICAL BOX TO CONDENSING UNIT
FREEZER: CONN-1 FROM ELECTRICAL BOX TO CASE
FREEZER: CONN-2 FROM ELECTRICAL BOX TO CONDENSING UNIT