10
Author: Rudi
Version: 2.2
Revision: 1.3
Revision Date: August 2020
SERVICE NOTES
ROUTINE MAINTENANCE
It is recommended that a suitably qualified person service this
appliance at least once a year.
-
Inspect the gas hose for cracks and chafing marks. Test all
connections with a suitable solution,
do not use an open flame
.
-
Check there is no smell of ammonia or any signs of green/yellow
crystal-like deposits on the cooling unit tubes. Smell or deposits
indicate a leaking unit – see User instructions.
-
Check the functioning of the flame failure control – adjust if
necessary.
-
Check the functioning of the ignition device if fitted – adjust if
necessary.
-
Check the control knobs turn freely.
-
Examine the burner flame – ensure burning with a sharp blue flame
and no yellow tipping or sooting.
-
Check the door/lid seals are in good condition.
IN THE EVENT OF FAILURE
If the burner will not light:
-
Check adequate gas supply – through to burner.
-
Depress flame failure device for 15sec and try lighting with a match.
This must be done in a well ventilated area!
QUALIFIED TECHNICIAN
-
Check jet is clean – if not, clean with solvent and blow dry. Do not try
to clean with pin or similar.
-
If the burner will not stay alight, check position of the flame
thermocouple head, and the functioning of the safety valve.
If not cold enough:
-
Check through points listed under Troubleshooting.
-
In the unlikely event of cooling unit failure, contact the national
distributor without delay.