![ZEPIRO D2O FL1 Product Manual Download Page 27](http://html1.mh-extra.com/html/zepiro/d2o-fl1/d2o-fl1_product-manual_3431251027.webp)
D2O FL1 Product Manual - 23
COMMAND SYNTAX
DETAILS
sys -p
<State>
Sets the Battery’s Power Switch State. The Available Parameters for
<State>
are:
ON
OFF
Admin Restricted - Cannot be set until the
admin
command has been executed
The device will remained powered by the USB connection, even after the
OFF
parameter is
used. Disconnecting the USB cable after the
OFF
parameter is set will shut down the D2O.
This setting is applied immediately upon carriage return (
Enter
Key).
IMPORTANT NOTE:
Ensure the D2O’s
Battery Power
has been enabled through the CLI
before leaving the D2O for its normal operation. No samples or
transmissions will occur if the
Battery Power
is off.
Example: Turning the Battery Power Switch State to ON. OK message displayed when successful.
sys -p ON
OK
COMMAND SYNTAX
DETAILS
sys -P
<password> <password>
Sets a new administrator password.
This is an
Admin Restricted c
ommand and cannot be set until the
admin
command has
been executed.
To minimise the risk of saving a password with a typing mistake, the parameter for
<password> must be entered twice, separated by a space. The password itself must be a
single, continuous string of characters with no spaces.
IMPORTANT NOTE: It is critical to remember the password as there is no mechanism for
Zepiro to reset the password in the event it is forgotten.
Example: Setting the administrator password to be
ab3Rq46
. OK message displayed when successful.
sys -P ab3Rq46 ab3Rq46
OK
COMMAND SYNTAX
DETAILS
sys SC
<1000 to 50000> <code>
Resets the battery capacity after replacement to allow for correct ongoing system power
estimates to occur.
The first parameter Requires battery pack capacity to be entered in milliamp hours (mAh) in
a range between 1000 mAh to 50000 mAh.
The second parameter is a special permissions code generated on request by Zepiro.
This process cannot be completed without a new factory supplied battery kit. Please
contact your Zepiro dealer for assistance.
Example: Setting the battery capacity to be 10,000 mAh and an example permissions code of
H42st5Pb
. OK message displayed when
successful.
sys SC 10000 H42st5Pb
OK