12
www.zephyronline.com
Installation –
Internal Blower (Horizontal Ducting)
1. Attach capacitor box to inside of hood using two
M4*10 screws included with internal blower.
2. Attach green ground wire to ground screw on
hood.
3. Connect 6 pin male connector from capacitor
box to 6 pin female connector on control board
box.
4. Place solid mounting plate on top of hood and
secure using eight M4*8 screws.
5. Remove rectangular cap from back of hood.
Place six M4*8 screws aside for later use.
6. Attach blower brackets to blower as shown above
using two M3.5*10 screws for each bracket.
There are two brackets total, one for each side of
the blower. NOTE: Drilled fl ange of both blower
brackets faces away from the blower casing.
INTERNAL BLOWER PREPARATION – HORIZONTAL DUCTING
Summary of Contents for CACHE CCA-E30ASX Use
Page 2: ...www zephyronline com...