Errors  Management:

  this  functionality  allows  the  sending  of  messages  to 

the  bus  informing  about  errors.  Errors  management  handles  Daikin  error 
codes as well as any communication errors that may arise 

Besides  informing  about  the  apparition  of  possible  errors  it  can  be  also 
configured the sending of the error type.  

In case of internal errors, the numerical code associated to the error type is 
shown in the following table: 

Error Number  

Type of Internal Error 

Problems with the data reception (speed, parity, etc.) 

Communication waiting time exceeded (Time-out) 

Incorrect checksum  

Incorrect response from the machine 

Regarding  the  numerical  code  associated  to  the  external  errors  type,  look 
up  the  manual  of  the  installed  air-conditioning  system  or  the 

Annex  II 

Correspondence Error Codes of Daikin Units

 

Initial Configuration: 

 

All machine status must have an initial value after installing the system or a 
power  failure.  With  this  purpose,  it  has  been  included  in  the  KLIC  the 
possibility of defining the initial status for the ON/OFF, temperature, fan and 
speed of the machine. 

These initial values can be sent both to the bus KNX and the air conditioning 
unit. 

 

Type of Control: Master/Slave 

It is important to take into account the type of control, 

master

 or 

slave

, with 

which the KLIC-DI is going to be configured. 

The  remote  control  “master”  in  the  installation  is  in  charge  of  the 
communication  with  the  machine  and  it  will  retransmit  the  instructions  and 
status between the machine and the slave remote control in case of having 
one. In spite of the master/salve configuration, all the functionalities can be 
set from both remote controls. 

This functionality allows including in the installation both

 

the KLIC-DI and the 

Daikin  wired  control  and  choosing  the  desired  master/slave  configuration 
whenever  the  KLIC-DI  and  the  wired  control  are  not  configured  with  the 

Summary of Contents for KLIC-DI

Page 1: ...KLIC DI INTERFACE KNX DAIKIN ZN1CL KLIC DI Edition 4 0 Version 1 4 PRODUCT MANUAL...

Page 2: ...1 Basic Control 8 3 2 Advanced Functionalities 8 4 Parameterization 12 4 1 Default Configuration 12 4 2 General 14 4 3 Mode 15 4 4 Fan speed 15 4 5 Scenes 17 4 6 Temperature Limitation 18 4 7 Automati...

Page 3: ...nication bus of the unit the KLIC DI will communicate with this remote control acting one device as master control while the other device will act as slave control It is important to verify that the K...

Page 4: ...ning functionality Error management handles Daikin error codes as well as any communication errors that may arise LED indicators allow monitoring of the bidirectional traffic flow Integrated EIB KNX B...

Page 5: ...rom Daikin is also used it is necessary to make sure that the wired remote control is in mode slave if the KLIC DI is configured as master control And vice versa if the KLIC DI is configured as slave...

Page 6: ...tes bidirectional communication between KLIC DI and Daikin unit Diagrams Leyend A KLIC DI B Daikin Wired remote control C Daikin SKY or VRV unit P1 P2 Daikin connection bus 1 2 Zennio connection termi...

Page 7: ...emote control Besides including the programming red LED typical in any KNX device the KLIC DI incorporates two more LEDs blue and green ones in order to inform about the bidirectional communication be...

Page 8: ...it updates the status of the corresponding parameter in the bus KNX 3 2 ADVANCED FUNCTIONALITIES Besides the basic control over the air conditioning system KLIC DI offers other advanced functionaliti...

Page 9: ...e Daikin installer it establishes the corresponding auto mode 3 The machine establishes the auto mode according to the average value of the Reference temperature and the Indoor temperature The tempera...

Page 10: ...itial Configuration All machine status must have an initial value after installing the system or a power failure With this purpose it has been included in the KLIC the possibility of defining the init...

Page 11: ...ount When switching the type of control of the Daikin wired control between master and slave it is necessary to remove the power supply from the wired control and connecting it again for rebooting the...

Page 12: ...utton on the device and select Edit Parameters for starting with the configuration In the following sections there is a detailed explanation about each of the different functionalities of the device i...

Page 13: ...s and the Simplified Modes Cool Heat are disabled by default while the Fan is configured for 2 different fan speeds and the step control is also disabled In the next figure it can be watched the avail...

Page 14: ...s we select the functionalities in the pull down lists the access to the functionality configuration window will appear in the Menu at the left and the corresponding communication objects are enabled...

Page 15: ...communication objects for controlling and indicating the Mode that exist by default If the option Individual Modes is activated the operating mode of the machine will be sent by means of the 1 bit Sen...

Page 16: ...ls the fan speed percentages will be interpolated in the following way Initial Speed Percentage Interpolated Speed Percentage Level 0 49 25 Minimum 50 100 100 Maximum Three Levels of Fan On the other...

Page 17: ...the speed level is at 100 the level will remain at this maximum until the speed is decreased 4 5 SCENES A scene involves the synchronized sending of several commands to the air conditioning unit with...

Page 18: ...nge minimum medium o maximum 4 6 TEMPERATURE LIMITATION The air conditioning unit has defined upper and lower temperature limits that cannot be exceeded the limits are usually 32 C and 16 C respective...

Page 19: ...nd the personalized ranges will control the unit performance when it switches on 4 7 AUTOMATIC SWITCH OFF When this option is enabled the air conditioning unit will be temporarily switched off if a st...

Page 20: ...ne status after the installation or a power failure The variables that can be initialized are the following ON OFF Last ON or OFF Temperature Last or custom Mode Last auto heat dry fan or cool Fan Las...

Page 21: ...ZENNiO AVANCE Y TECNOLOG A www zennio com 2 1 Figure 16 Initial Configuration...

Page 22: ...um 1 20 Medium 21 60 Maximum 61 100 Auto 0 Minimum 1 20 Minimum Medium 21 40 Medium 41 60 Medium Maximum 61 80 Maximum 81 100 4 1 bit R T 0 1 ON OFF Status Split State ON OFF 5 2 bytes R T 10 32 Tempe...

Page 23: ...Dry Mode 1 Nothing 0 MODE 13 1 bit I W 0 1 Simplified Mode Cool 0 Heat 1 14 1 bit R T 0 1 Auto Mode Status Auto Mode Enabled 1 Disabled 0 15 1 bit R T 0 1 Cool Mode Status Cool Mode Enabled 1 Disabled...

Page 24: ...339 M2 387 T2 435 X2 4 03 52 E3 100 J3 148 U3 196 73 244 43 292 13 340 M3 388 T3 436 X3 5 04 53 E4 101 J4 149 U4 197 74 245 44 293 14 341 M4 389 T4 437 X4 6 05 54 E5 102 J5 150 U5 198 75 246 45 294 15...

Page 25: ...8 121 L8 169 98 217 68 265 38 313 G8 361 N8 409 V8 457 Y8 26 A9 74 H9 122 L9 170 99 218 69 266 39 314 G9 362 N9 410 V9 458 Y9 27 AA 75 HA 123 LA 171 9A 219 6A 267 3A 315 GA 363 NA 411 VA 459 YA 28 AH...

Page 26: ...E ERROR BUS DAIKIN CODE 41 C8 89 F8 137 P8 185 88 233 58 281 28 329 K8 377 R8 425 W8 473 Z8 42 C9 90 F9 138 P9 186 89 234 59 282 29 330 K9 378 R9 426 W9 474 Z9 43 CA 91 FA 139 PA 187 8A 235 5A 283 2A...

Page 27: ...2 7 2 7 ZENNIO TECHNICAL DOCUMENTATION SIGN UP http zennioenglish zendesk com TECHNICAL SUPPORT...

Reviews: