Figure 9. 

Notification LED 

– Green, Yellow and Red

 

 

Figure 10. 

Notification LED 

– Green and Yellow

 

The threshold values should be set from highest to lowest (from top to bottom). If this 

indication is not met, default values will be taken. In addition, an alert message will be 

shown.   

Incorrect yellow threshold values. The default values will be downloaded in 

case of an incorrect parameterisation.  

 

 

Summary of Contents for FlatSensato

Page 1: ...FlatSensato KNX Humidity and Temperature sensor for flush mounting ZS FSEN USER MANUAL Application Program Version 1 0 User Manual Version 1 0 _a www zennio com...

Page 2: ...o 3 1 2 Installation 4 2 Configuration 6 2 1 General 6 2 2 Temperature 8 2 3 Humidity 11 2 4 Dew Point 14 2 5 Notification LED 16 2 5 1 Configuration 16 2 6 Inputs 18 2 6 1 Binary Inputs 19 2 6 2 Temp...

Page 3: ...e and condensation The most outstanding features and functions of the device are Measurement of dry air temperature Measurement of relative air humidity indoor Measurement of dew point temperature Ala...

Page 4: ...of the device Once the input terminal and the KNX terminal are connected the device can be easily mounted on the metallic plate by the action of the fixing clips Finally it is advisable to check that...

Page 5: ...mming Mode After a short press the programming LED 4 will light in red Note that if this button is held while plugging the device into the KNX bus the device will enter the Safe Mode The LED will then...

Page 6: ...isables the Inputs tab in the tree on the left depending on whether the device will or will not be connected any external accessories See section 2 6 for details Logic Functions enables or disables th...

Page 7: ...eriodically with value 1 to notify that the device is still working still alive Figure 4 Heartbeat Periodical Alive Notification Note The first sending after download or bus failure takes place with a...

Page 8: ...ation Temperature Sensor Calibration defines an offset to be applied to the measurement received from the probe to correct deviations due to external factors The offset should be in the range 50 50 te...

Page 9: ...at alarm has been triggered the no alarm will not be sent until the current temperature is lower than that T minus the hysteresis After that if the current temperature reaches T again the alarm will b...

Page 10: ...Flat Sensato http www zennio com Technical Support http support zennio com 10 Overheating Temp Overcooling Temp Hysteresis The three of them are analogous to those already explained separately...

Page 11: ...iguration Humidity Sensor Calibration defines an offset to be applied to the measurement received from the probe to correct deviations due to external factors The offset should be in the range 12 12 t...

Page 12: ...s fluctuating around the limit H once the alarm has been triggered the no alarm will not be sent until the current humidity is lower than that H minus the hysteresis After that if the current humidity...

Page 13: ...ysteresis After that if the current humidity reaches H again the alarm will be re sent Low Humidity and High Humidity high humidity and low humidity alarms are enabled The following three parameters w...

Page 14: ...ime the value of the current dew point temperature should be sent to the bus through Dew Dew Point Temperature in the range 0 255 tens of second The value 0 leaves this periodical sending disabled Sen...

Page 15: ...egree the default is 20 tenths of a degree around the dew point This dead band prevents the device from sending the condensation alarm and no alarm over and over when it keeps fluctuating around the l...

Page 16: ...default threshold values Figure 8 Default colors of Notification LED ETS PARAMETERISATION After enabling Notification LED see section 2 1 a new tab will be incorporated into the tree on the left The p...

Page 17: ...e 10 Notification LED Green and Yellow The threshold values should be set from highest to lowest from top to bottom If this indication is not met default values will be taken In addition an alert mess...

Page 18: ...on detector models ZN1IO DETEC P and ZN1IO DETEC X from Zennio Important older models of the Zennio motion detector e g ZN1IO DETEC and ZN1IO DETEC N will not work properly with Flat Sensato ETS PARAM...

Page 19: ...f Flat Sensato Please refer to the Motion Detector user manual available in the Flat Sensato product section at the Zennio website www zennio com Notes The ZN1IO DETEC P motion detector is compatible...

Page 20: ...xecution of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after ex...

Page 21: ...d saturation On the other hand as air temperature increases the capacity to hold water increases as well This means that keeping the absolute humidity constant the relative humidity varies with the ai...

Page 22: ...y 0 No Alarm 1 Alarm 10 2 Bytes I C W DPT_Value_Temp 273 00 670760 00 Dew Surface Temperature Input Surface Temperature Value 11 2 Bytes O C T R DPT_Value_Temp 273 00 670760 00 Dew Dew Point Temperatu...

Page 23: ...n 1 Bit C T DPT_Switch 0 1 Ix Short Press Light Off Sending of 0 Off 1 Bit I C T W DPT_Switch 0 1 Ix Short Press Light On Off Switching 0 1 1 Byte C T DPT_SceneControl 0 63 128 191 Ix Short Press Run...

Page 24: ...t C T DPT_Step 0 1 Ix Long Press Stop Step Down Shutter Sending of 1 Stop Step Down 1 Bit C T DPT_Step 0 1 Ix Long Press Stop Step Shutter Switched Switching of 0 1 Stop Step Up Down 4 Bit C T DPT_Con...

Page 25: ...Alarm 0 1 Ix Overcooling 0 No Alarm 1 Alarm 28 32 1 Bit O C T R DPT_Alarm 0 1 Ix Overheating 0 No Alarm 1 Alarm 29 33 1 Bit O C T R DPT_Alarm 0 1 Ix Probe Error 0 No Alarm 1 Alarm 34 1 Byte I C W DPT_...

Page 26: ...5 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 1 Bit I C W DPT_Bool 0 1 LF 1 bit Data Entry x Binary Data Entry 0 1 126 127 128 1...

Page 27: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: