background image

Quick Start Installation Guide

 

806836NZ v1.02 02.22 G5 B BA Quick Start Guide

1

Q

uick Start Installation Guide

Command Centre
Boiling, Boiling / Ambient models 

AFFIX PRODUCT LABEL HERE

Zenith 

HydroTap G5

Visit our website to 

download the manuals

Summary of Contents for HydroTap G5 B

Page 1: ...tion Guide 806836NZ v1 02 02 22 G5 B BA Quick Start Guide 1 Quick Start Installation Guide Command Centre Boiling Boiling Ambient models AFFIX PRODUCT LABEL HERE Zenith HydroTap G5 Visit our website to download the manuals ...

Page 2: ...CTIONS 4 SECTION 3 WARNINGS REGULATORY INFORMATION 6 SECTION 4 Technical data 8 SECTION 5 Parts supplied 9 SECTION 6 Set up the ventilation 10 SECTION 7 Connect the water supply 12 SECTION 8 Set the bypass install the Limescale filter 13 SECTION 9 Fit the Booster 14 SECTION 10 Connect the Booster 15 SECTION 11 Connect the Command Centre 16 SECTION 12 Commissioning 19 ...

Page 3: ...urther details on installing and operating your HydroTap download read the Command Centre installation and user instructions which can be found online at zenithwater co nz Read and use the instructions supplied with individual kit components for a safe installation Before you start Explanation of symbols Read the instructions WARNING Danger of electric shock Hot surface ...

Page 4: ... cable and power outlet must be in a safe visible position for connection Venting Sometimes steam and or boiling water droplets may discharge through a vent outlet on the tap If not using the font ensure the tap body is located so the tap outlet safely dispenses into the sink bowl Lifting Take care when lifting The Command Centre may exceed safe lifting limits If you feel this is beyond your perso...

Page 5: ...artup calibration and will recalibrate itself on a regular basis Frost protection If the HydroTapis located where the ambient air temperature could fall below 5º C when the system is not in use do not turn off the Command Centre electrically This safeguard does not offer the same protection to the connecting pipework and fittings Application The HydroTap G5 Home series is intended to be used in ho...

Page 6: ...lating the appliance from the power supply Connect only to a potable wholesome cat1 mains water supply Never locate the system near or clean with water jets Do not expose the Zenith HydroTap to the elements of nature SECTION 3 WARNINGS REGULATORY INFORMATION The booster complies with protection class IP 20 For UK a pressure limiting valve must be fitted for mains water pressures above the maximum ...

Page 7: ...e power supplies at the rear of the appliance For safe operation the HydroTap is designed to be installed commissioned and used within 48 hours Should the HydroTap not be required for an extended period of time 72 hours or more do not fill and commission the HydroTap until ready for first use For water taste and quality reasons following any non use period of more than 72 hours Zenith recommends t...

Page 8: ... specification Specification Rating Nominal power 2 2kW Nominal current 10A Flow rate 1 2 L m Water supply pressure requirements Component Power rating kW Dimensions W x D x H mm Weight kg B100 BA100 1 8 2 2 280 x 313 x 333 13 B60 BA60 1 8 280 x 313 x 335 13 B BA Home 1 35 280 x 313 x 335 13 power rating of the booster Component Min Max pressure kPA bar NZ Australia HydroTap 170 1 7 700 7 0 Vented...

Page 9: ...and Centre Command Centre Mains electrical supply cable Water supply inlet hose Water supply inlet adaptor and strainer Ventilation kit Water block kit UK only UK only Booster Booster hoses Optional Filters Water filter instructions Limescale filter kit Optional Optional Font Font kit Optional Optional Note Mains water isolation valve is not supplied with the kit Contact Zenith for the full range ...

Page 10: ...1 02 02 22 G5 B BA Quick Start Guide SECTION 6 Set up the ventilation Command Centre width A clearance envelope around all Command Centres must be provided to allow ventilation for the safe and effective use of the HydroTap system 200mm 50mm 50mm ...

Page 11: ...on is required Contact your Zenith service provider for options including additional vents and fan kit All models Cold air is drawn in through the inlet vent and lower gap provided by the door buffers Inlet vent is mounted over cupboard side door or floor cut out Warm air is exhausted through the upper gap provided by the door buffers SECTION 6 Set up the ventilation Air outlet Air inlet Air inlet...

Page 12: ...supplied Connect together Connect to Command Centre see page 17 18 Connect to Command Centre see page 17 18 Note Mixer tap installations also use a Tee piece as part of the water supply plumbing connections see the Tap installation instructions supplied with the Mixer Tap to connect the water supply if using the mixer tap option Valves and fittings must be sealed with PTFE tape if compression seal...

Page 13: ... in Bypass out see page 17 18 Water out Bypass in see page 17 18 Insert Remove Insert Remove For filter head installation use the guide supplied with the filter head For Limescale filter installation use the guide supplied with the filter Bypass valve Rear of the Command Centre Flush filter before use Available as optional accessory UK only ...

Page 14: ...36NZ v1 02 02 22 G5 B BA Quick Start Guide SECTION 9 Fit the Booster a b c d e f 10 15 Note Take care not to break the clips when removing or installing the Booster Supplied with selected models or available as an optional accessory Booster ...

Page 15: ...h spanner while tightening hoses 3 8 BSP connections Do not connect to electrical power until commissioning Do not over tighten hose connections Braided hoses supplied cannot be lengthened Strainer Cold water into Booster connect to Command Centre BYPASS OUT see page 17 18 Hot water out of Booster connect to Command Centre BYPASS IN see page 17 18 ...

Page 16: ... cable Do not connect to the mains socket until commissioning Installation diagrams are for illustrative purposes only Hoses are not shown to scale and cannot be lengthened Tips for hose connection Push the silicone hose over the connector for a minimum of 15mm Ensure there a constant fall from the tap down to the command centre Hoses must be trimmed to avoid loops and kinks Take care when positio...

Page 17: ... BOILING OUT BYPASS IN VENT BYPASS OUT B res comm USB MAINS IN C 175 comm USB CHILLED OUTLET CS 175 comm check positi check which way round still sparkling USB AINS N AINS IN Mains Water Zenith Vented Mixer Tap connections if supplied B60 B100 B Home models Example installation Diagram for illustrative purposes only Hoses are not shown to scale as the Booster hoses cannot be lengthened B Res Comm ...

Page 18: ...RKLING OUTLET CO2 IN USB BCS res MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT AMBIENT OUTLET USB BA res comm C res CHILLED OUTLET MAINS IN USB CS75 res CO2 CHILLED SPARKLING MAINS USB USB AINS N AINS IN Mains Water Zenith Vented Mixer Tap connections if supplied BA60 BA100 BA Home models Example installation Diagram for illustrative purposes only B Res Comm BA Res Comm RED BLU...

Page 19: ...cartridge a quarter turn anticlockwise until it comes to a complete stop and locks with the front label facing forward Turn on the supplies familarize yourself with the system Connect the mains electrical power cable to the supply Turn the power and water on and check for any leaks Familiarise yourself with the operation of the tap and GUI screen in preparation for use see the user guide Select th...

Page 20: ...make adjustments When ready touch the arrow to continue 12 12 PM DRAIN AWAY OPTION Does your tap drain into a Or Sink Container Font If you are not clear on your selection options refer to the commissioning instructions Select Sink Container or Font depending on the model see below Select Font if the HydroTap is mounted on a font Select Sink Container if the HydroTap is mounted such that the waste...

Page 21: ...an of the filter in filter settings 12 12 PM FILTER FLUSH STEP 1 Open the filter access door and turn the flush line STOP COCK VALVE to the ON position STEP 2 Place a 10L bucket under the flush line valve to catch the water flushed through the filter Filter flush Follow the steps on screen to flush the filter Open filter door uncoil flush line Direct flush line into bucket Place a cloth or towel u...

Page 22: ...ow the prompts on the screen to utilise the tap and its safety feature to empty the hot tank If Auto Dispense is disabled the tanks will fill automatically When prompted use the tap to dispense water and empty the tanks If the hot tank has water above 50 C then use the taps safety feature to dispense B BA Models 12 12 PM TANK FLUSH Fresh water will be flushed through the tank s multiple times as s...

Page 23: ...ght intensity varies from site to site therefore it is recommended that a re calibration be performed at the time of the installation All direct sunlight must be shaded from the HydroTap during the calibration This can be achieved by closing any nearby curtains blinds etc Shield the HydroTap from direct sunlight In normal operating mode Turn the power off Pull both tap levers to the forward positi...

Page 24: ...G5 B BA Quick Start Guide Refer to User Guide for operation and maintenance Zenith Heaters Limited IRD GST No 95 640 729 18 Kawakawa Place Westgate Auckland 0814 New Zealand Ph 64 9 838 8612 Free Call 0800 558 055 zenithwater co nz AU02691 WMKA00099 AS 3498 ...