803341NZ - HydroTap Taps Install Instructions 09.18 v2.11
John Guest fittings (insertion and removal)
NOTE:
Be careful when cutting the poly tube so that there are no rough edges and that the tube is not distorted.
1. Use a sharp knife to ensure the tube has a clean, straight
edge. Do not cut at an angle.
2. Remove any swarf or unwanted material.
3. Push the tube into the John Guest fitting making sure all
connections to the John Guest fittings are pushed in past the
“O”ring to full depth, at least 15-16mm.
4. Check for a good joint by pulling back on the tube. If the tube
comes out of the fitting, repeat the above step.
5. To remove the tube, press the collet into the fitting and at the
same time pull back on the tube.
Installation Instructions - HydroTap Arc / Cube
2.5
Tube kit assembly
NOTE:
The L/H & R/H
positions of
the three way
silicon tube are
interchangeable
Type C
Chilled Sparkling
Used with BCS only
Type B
Chilled
Type A
Boiling
Type D
Sparkling
Type E
Chilled / Ambient
Red
Silicon
Blue
Silicon
Blue / White
LLDPE
White
LLDPE
Blue
LLDPE
Type F
S/S Tube
Three way
silicon tube
S/S tube
20mm
insertion
Fig. 1
Clamp Herbie
clip near the end
of the three way
silicon tube
Fig. 2
General Fitting Instructions
Once the ARC and CUBE HydroTaps have been secured to the benchtop or sink, it will be necessary to
connect the relevant tube kit to the three way silicon tube as follows: (See below for specific tube kit assembly
instructions)
•
Insert the 1/4” Blue and White JG tubes into their respective JG fittings as shown above (Type C-E)
•
Ensure all connectors and tubes, are pushed fully home into the JG fittings (see below).
•
Assemble tubes in accordance with the instructions overleaf. Check the insertion depth as shown in
Fig.1.
•
For Maximum grip on all three connectors, ensure the Herbie clip is clamped close to the end of the
three way silicon tube and aligned with the central axis, as shown in Figs.1 & 2