Operating the Tap

Blue Chilled Water Light
On all the time: 

This indicates that the chilled water temperature is within the usable range.

Flashing slowly : 

This indicates that the chilled water is not at the right temperature. Wait up to 
20 minutes.When the chilled water is ready, the light will stop flashing.
Note: The Zenith HydroTap is designed to dispense chilled water in the temperature
range 5°C to 10°C.

During heavy usage, the temperature can rise out of this range.

Red Boiling Water Light 
On all the time: 

This indicates that the boiling water is ready.

Flashing slowly : 

This indicates that the boiling water is below usable temperature.

Filter Change Light Off:

This indicates the filter is operating within its normal specified lifespan.

Filter Change Light Flashing slowly :

The light will flash slowly when the filter is due for replacement and the LCD will
show “Filter Change”. Refer to  "Replacing the filter" section of this document.

Boiling Water Lever    

Depressing the “Red” lever allows dispensing of boiling water. Pulling up the 
Red lever allows the tap to operate in a “no-touch” mode. Water will flow for a
maximum time of 15 seconds. To reset, return the handle to the “Off” position
and repeat the step. The lever has to be manually returned to the “Off” position.

Chilled Water Lever

Depressing the “Blue” lever allows dispensing of chilled water. Pulling  up  the
Blue lever allows the tap to operate in a “no-touch” mode. Water will flow for a
maximum time of 15 seconds. To reset, return the handle to the “Off” position and
repeat the step. The lever has to be manually returned to the "Off" position.

Child Proof Lock (boiling / chilled models)

The child proof lock can be activated to prevent boiling water flowing if the hot
lever is inadvertently activated.

To activate

, first press the safety button then

depress the Blue chilled water lever for a period of approximately ten seconds. The
safety lock indicator light will now be illuminated.

To de-activate

, first press the

safety button then depress the Blue chilled water lever for a period of
approximately ten seconds. The safety lock indicator light will now extinguish.

To

operate when the lock is "ON"

, depress both the Red lever and the safety button

simultaneously.

Child Proof Lock (all boiling only models except HT models)

To activate the child safety lock, go to the LCD display, using menu 

or

scroll to

the Child Safety Lock display. To turn ON adjust 

to turn OFF adjust 

button.

After about 10 secs the screen will default to the selected mode.  When  activated
the LED on the safety lock will be illuminated. When de-activated the LED will be off.

Child Proof Lock (HT boiling only models)

Pressing the safety button rapidly three times will either activate or de-activate the lock.
Indicator light ON means the lock is active, indicator OFF means the lock is inactive.

Child safety Lock

Note:

On the Boiling only models

the Chilled LED is blank.

Summary of Contents for HYDROTAP 30009

Page 1: ...droTap Filtered boiling and chilled drinking water for kitchens and tea rooms Commercial Models 30281 Zenith HydroTap BC150 175 30271 Zenith HydroTap BC100 125 37201 Zenith HydroTap B10OF 38201 Zenith...

Page 2: ...all models 7 Step E Testing and commissioning 7 Font Installation procedure 8 Operating the Tap 9 Cleaning 10 Replacing the Filter 10 Pull out Font Template pages a b c d Setting the Energy Saver Tim...

Page 3: ...e given in the table under the heading Installation Requirements Do not lift the unit by the doors Airflow The ambient temperatures this unit should operate within are 5 C 35 C Proper air circulation...

Page 4: ...750 mm flexible connection and positioned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed Power supply 220 240 Volt AC for connection to the...

Page 5: ...lide it up to meet the All Thread and pass the All Thread through the center of the Spider Clamp 7 Hold the All Thread steady and re fit the 6mm nut to the All Thread using the tube spanner supplied i...

Page 6: ...essential Step C Connecting the tap Model BC and HT boiling chilled models Measure and trim the blue tube and connect it to the chilled water outlet located on the top front right hand side of the nde...

Page 7: ...e water to 95 C maintaining it at that temperature for a short stabilization period Once stabilized the element will cycle On bring the water to boiling point and hold it there for a short period The...

Page 8: ...e fixing nut withtheTube Spanner provided in the kit NOTE The All Thread is a floating component it locks into place once tension is applied by the fixing nut and washer 6 Tighten the securing pin so...

Page 9: ...he Blue lever allows dispensing of chilled water Pulling up the Blue lever allows the tap to operate in a no touch mode Water will flow for a maximum time of 15 seconds To reset return the handle to t...

Page 10: ...il it stops 4 Ease cartridge downwards to detach it from the filter head socket 5 Do not tilt the cartridge as dirty water may spill from it if tilted 6 Unpack replacement cartridge and write today s...

Page 11: ...ions section of this document Press either Mode or Mode button until Litres Filtered is displayed Press Adjust once and Reset Counter will be displayed press Adjust button once and Are You Sure will b...

Page 12: ...is the most effective for your installation Application of the fan is of paramount importance in situations where the cupboard space reaches temperatures greater than 35 C Boiling Water Safety Isolati...

Page 13: ...ust come out of OFF cycle Possible internal fault Excessive use unit refilling or chilling down to temperature Possible internal fault Check power supply Ensure power plug is correctly fitted and swit...

Page 14: ...tor kit BC150 175 17 Z90023 compressor kit BC150 175 7 Z90633 sensor probe kit 18 Z90639 fan motor kit BC100 125 8 Z90634 pump kit cold 18 Z90640 fan motor kit BC150 175 9 Z90622 PCB kit BC100 125 BC1...

Page 15: ...kit hot tank BC100 125 4 Z90617 gasket and elbow kit BC 150 175 16 Z90630 level sensor kit hot tank BC150 175 5 Z90579 overload kit 17 Z90186 loom overlad kit 6 Z90618 element 1500W kit 18 Z90187 loom...

Page 16: ...e Solenoid Kit 4 Z90658 Gasket and Elbow Kit BC 100 125 5 Z90579 Overload Kit 6 Z90618 Element 1500 watt Kit 7 Z90620 Sensor Probe Hot 8 Z90621 Pump Kit Hot 9 Z90689 PCB Kit Boiling Only 10 Z90624 Lea...

Page 17: ...Zenith Hydro Tap Installation and Operating Instructions 81467 February 2005 Page 17 of 20 Notes...

Page 18: ...Page 18 of 20 Zenith Hydro Tap Installation and Operating Instructions 81467 February 2005 Notes...

Page 19: ...Zenith Hydro Tap Installation and Operating Instructions 81467 February 2005 Page 19 of 20 Notes...

Page 20: ...osts are payable by the customer other than any mileage or travelling time charges incurred by a Zenith Service Provider or the cost of removal cartage and re installation of any component of the appl...

Reviews: