INSTALLER MENU
3828VD0171G
2-5
DIGITAL FCS - INSTALLER MENU
80-I. UPN MSB-2
User programmable number, most significant byte-
2 readable by M.P.I. command. (SN-HIGH)
81-I. UPN LSB
User programmable number, least significant byte
readable by M.P.I. command. (SN-LOW)
82-I. CHKSM ERROR
Enforces rigid M.P.I checksum validation.
Set to 1 for validation.
Set to 0 to turn off.
83-I. HANDSHK TIME (Handshake Time)
Adds an additional delay to the handshake time
which is 64 msec, thus relaxing M.P.I. timing
requirements to be compatible with PC based Win-
dows controlled systems, range is 0 - 5.
Set to 0 to retain standard 64 msec delay. Set
to 1 - 5 to increase @ 16 msec ea., the delay up
to 144 msec.
84-I. PERMANENT BLK (Permanent Block)
Allows Parental Control blocking schemes to be
permanent by removing the blocking hours func-
tion.
Set to 1 to install Parental Control blocking
restrictions permanently. Set to 0 for user-
specified hours control of blocking schemes.
85-I. A. MUTE TIME (Audio Mute Time)
Controls audio muting delay time when switching
between AUX sources. Range is 0 to 254 msec.
86-I. V. MUTE TIME (Video Mute Time)
Controls video muting delay time when switching
between AUX sources. Range is 0 to 254 msec.
87-I. NOT USED
88-I. EN NOISE MUTE (Enable Noise Mute)
Enables soft mute when a signal is not present.
89-I. POKE ENABLE
Enables poke function through M.P.I. commands.
90-I. NOT USED
91-I. NOT USED
92-I. NOT USED
93-I. NOT USED
94-I. NOT USED
95-I. NOT USED
96-I. NOT USED
97-I. NOT USED
98-I. NOT USED
99-I. NOT USED
100-I. NOT USED
101-I. NOT USED
102-I. NOT USED
103-I. NOT USED
104-I. NOT USED
105-I. NOT USED
106-I. A RATIO LOCK (Aspect Ratio Lock)
If set to 1, current picture aspect ratio is
retained at power Off. At power On, previous
aspect ratio will be used. If set to 0, resets
aspect ratio to default setting at TV turn On.
FACTORY MENU
ACCESSING THE FACTORY’S MENU
Using the remote control or the keyboard on the
front panel can access the Factory’s Menu items.
With the remote, just press and hold MENU (about
8 seconds) until the display changes, then press
1, 9, 3, 7, then ENTER. To exit the Factory’s
Menu, press ENTER again. Any changes you make
will be stored in nonvolatile memory. To access
the Factory Menu with the set’s keyboard press
and hold the MENU key until the Ch/Time display
appears, simultaneously press the ADJUST RIGHT
& CHANNEL UP keys.
USING THE FACTORY MENU
The Factory Menu has two pages, the Factory Menu
1 and the Factory Menu 2. The Factory Menu 1 is
to control or modify the main characteristics
of the CV RF, CV base band and Y/C signals. The
Factory Menu 2 is to control or modify the main
characteristics of the NTSC YUV and RGB Com-
puter input signals. Their numbers, descrip-
tions, ranges, factory default settings, and a
place for listing any changes made onsite are
given below and on the following pages.
The Factory’s menu opens with item 003-F VERT
POS item. Use the SELECT key to sequence through
the available menu items, or access an item
directly by entering the item number, and then
pressing MENU. For example, to access the item
015-F, press 1, 5, then MENU. To change the
settings use the Left/Right ADJ keys.