Pump Bolt Size
Bolt Material
Recommended
Torque
(lb.-in)
*
M4
316 SS
20
M6
316 SS
70
M8
316 SS
169
M10
316 SS
335
M12
316 SS
580
Mounting Bolt
Bolt Material
Recommended
Size
Torque
(lb.-in)
*
M10
Alloy
519
M12
Alloy
910
Trouble
Probable Cause
Remedy
Pump will not turn
1)
Drive malfunction
Verify that drive is powered.
Assure that alarm circuits are
clear. Check motor drive
current and speed settings.
2)
Process conditions
Check process conditions
changed
for proper temperature,
pressures, viscosities and
materials.
3)
Entrained particle
Disassemble and clean
pump; replace any damaged
parts.
4)
Possible internal
Disassemble and clean
damage
pump; replace damaged
parts. Consult factory.
Excessive seal
1)
Worn seal face(s)
Replace seal.
assembly leakage
2)
Improperly Positioned Check seal and faces for
seal or faces
proper position.
1)
Excessive outlet
Reduce outlet pressure.
pressure
Reduced pump
2)
Worn gear(s)
Replace worn gear(s).
efficiency
3)
Process conditions
Consult factory for gear
changed
clearance recommendations
for new process conditions.
Trouble-
shooting
Screw Torque
Examples of malfunctions of the pump with possible causes
and remedies are listed in the following table:
*Lubricated values/if non-lubricated increase by 33%.