2  Functional Description

30V

S

E

L

E

C

T

O

R

ST

AT

I

O

N

 

N

U

M

BE

R

1

1

12

12

Mic line

Speaker

line

+24 VDC

Line 12

Line 1

Line 2

GND

2

4

3

16

15
14
13
12

11

10

9
8
7

6

5

1

SW1

P10

6

5

4

3

1

2

HANDSET

AMPLIFIER

Q1-5

IC1

SIGNAL

TONE

Z2

D1-D12

C7

P6

P7

P11-P22

Z1

39V

NC

24

0V

23

HAND

CRANK

P8

P9

D17

+

+

+

D19

D21

TP11

TP12

TP13

INDUCTOR

MOTOR

J7/J8

J6/J6

Figure 2: 

Main station VSP-211-L principle diagram

2.1  Power

 

● An AC voltage appears between TP10/TP11 and TP12/TP13 when 

the hand crank is activated. This voltage is rectified in D19 and D21, 

providing DC power for two purposes: 

 -

Powering the amplifier

 -

Creating a call signal

 

L

P8 and P9 together with D17 enables the use of the board with the old inductor.

 

● When a call is being made, the actual line will carry a generated 

voltage. This voltage is fed through the active line via the 

corresponding diode D11 and D12 to the amplifier. 

 

● A permanent amplifier 24 VDC power can be supplied on the 

connection block terminal 23 (+) and 24 (-).

 

L

To avoid noise problems, the 24 VDC power supply must be connected via a DC/

DC converter.

 

L

Note that the circuit boards can be used as spare parts for the older VSP units. 

When using boards with inductors, remove jumpers from pins J6 and J7/J8 and 

insert a jumper on pin J9 located to the left of the DIP switches.

2.2  Calling

 

● The station’s extension number is set by DIP switches P11 - P22. 

 

This will activate the call signal generator in the called station and 

provide power to the amplifier.

 

● The desired station is selected by a 12-way rotary switch.

 

When turning the hand crank, a voltage is supplied to the selected 

line.

Summary of Contents for Vingtor Stentofon VSP 12-Way

Page 1: ...Amplified BatterylessTelephone System VSP 12 Way A100K10873 TECHNICAL MANUAL...

Page 2: ...3006200024 Main Station panel mounted indoor unit VSP 213 L 1020600935 Publication Log Rev Date Author Comments 4 0 2008 04 23 Published 5 0 2009 08 24 SEN JF New circuit board Some contents updates...

Page 3: ...Setting Extension Number 10 4 Operation 11 5 Troubleshooting 12 5 1 Conversation Lines 12 5 2 Call Tone 12 6 Specifications 13 6 1 Electrical Specifications 13 6 2 Certificates 13 7 DIP Switch Settin...

Page 4: ...ndependent of the vessel s power supply and fulfills the demands for emergency communication between vital locations onboard The VSP system described in this manual is a system comprising up to 12 mai...

Page 5: ...for weelhouse and control room VSP 223 L Main Station panel mounted with relay Alarm stop button Noise compensated microphone LED call indicator Bulkhead mount in on wall back box MBOKS Suitable for c...

Page 6: ...the board with the old inductor When a call is being made the actual line will carry a generated voltage This voltage is fed through the active line via the corresponding diode D11 and D12 to the amp...

Page 7: ...alling tone frequency is 2500 Hz It is not recommended to change the call tone frequency because it is adjusted to the mechanical resonance of the handset The call tone has a fluttering frequency at a...

Page 8: ...latch relay circuit for activating external audible and or visible signal units Additional terminals 17 22 are added for this feature Local 24 VDC for signal unit 17 24 V and 20 0 V Signal unit connec...

Page 9: ...1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 17 18 19 20 21 22 17 18 19 20 21 22 17 18 19 20 21 22 2 X 33 32 31...

Page 10: ...mber 1 Insert jumpers into pins J2 and J3 2 Activate the DIP switch on the PCB corresponding to the selected number by sliding it to the ON position Figure 4 DIP switch setting for extension no 2 For...

Page 11: ...er and without distortion for a guaranteed period of 20 minutes After 20 minutes the conversation period can be extended by turning the crank again By calling a station with a built in relay circuit f...

Page 12: ...der 5 2 Call Tone Extension numbers 11 and 12 do not work No call tone Jumpers on pins J2 and J3 are not inserted Insert jumpers on pins J2 and J3 located on the right side of the DIP switch Station r...

Page 13: ...ust and corrosion resistant construction and conform to the following Product Specifications IEC 533 2nd edition June 1996 EMC of Electrical and Electronic Installation in Ships and of Mobile and Fixe...

Page 14: ...9 Issued by China Classification Society Certificate no 16 LD1543066 PDA Valid until 2021 07 12 Issued by ABS American Bureau of Shipping Certificate no 11080100 Valid until 2019 08 13 Issued by Russ...

Page 15: ...ension No 6 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 7 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 8 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7...

Page 16: ...16 A100K10873 VSP 12 Way Batteryless Telephone System Technical Manual 8 Station Mounting Dimensions 8 1 VSP 122...

Page 17: ...17 VSP 12 Way Batteryless Telephone System Technical Manual A100K10873 8 2 VSP 122P...

Page 18: ...18 A100K10873 VSP 12 Way Batteryless Telephone System Technical Manual 8 3 VSP 211 L 8 4 VSP 213 L...

Page 19: ...19 VSP 12 Way Batteryless Telephone System Technical Manual A100K10873 8 5 VSP 223 L...

Page 20: ...part or in whole must include this legend Zenitel All rights reserved customer service zenitel com DOC NO A100K10873 The WEEE Directive does not legislate that Zenitel as a producer shall collect end...

Reviews: