7 Safety 

and 

Precautions 

7.1 Environmental 

Always ensure adequate ventilation is provided for 
the equipment and do not obstruct ventilation 
holes. 

The temperature and humidity ranges shown in 
the specifications for this product must not be 
exceeded.  

This equipment must not be installed in an area 
that is subject to a corrosive atmosphere, 
excessive moisture or may allow water or other 
liquids to come into contact with the unit or its 
external connections. 

7.2 Electrical 

Safety 

 
 

 

This product contains wiring that is 
energised 

to 

230 V RMS AC 

mains. 

 
 
 

 

Always ensure that the equipment 
is correctly earthed by connection 
to an AC mains supply with a 
protective earthing connection.  

Ensure power supply cabling is 
adequately rated for the unit’s 
operating current and protected, in 
case of short circuit, by a correctly 
rated fuse or circuit breaker. 

 
 
 

 

Always replace blown fuses with 
the correct type and rating. 

7.3 

Unpacking and Handling 

The equipment should be unpacked and 
inspected immediately on receipt. If damage has 
occurred please advise your carrier or supplier.  

It is advisable to retain the original equipment 
packing in the event that the equipment ever 
needs returning for service. 

Ensure that the name and address of the 
Authorised Distributor from whom you purchased 
the unit is recorded on the 

Service and Warranty

” 

page of this manual for future reference.  

Advice on packing the product for return can be 
provided by Application Solutions (Safety and 
Security) Ltd.. 

 

 

 

 

 

 

!

!

 

 

 

 

 

!

!

 

 

 

 

 

 

 

 

 

 

!

!

 

 

 

 

 

 

 

 

Issue: 03 complete, approved 

Page 21 of 24

 

Summary of Contents for RCS01

Page 1: ...plete approved 28 05 08 M0618_23 Date Part Number Product Manual RCS01 RPA Transmitter Charging Station Desktop version RPA Transmitter for illustrative purposes only ASL Document Ref U 0618 0103 doc...

Page 2: ...Security Ltd assumes no liability with respect to the accuracy of such information Issue 03 complete approved Page 2 of 24 This equipment is designed and manufactured to conform to the following EC s...

Page 3: ...2 Desk Mount Installation 9 3 3 Wall Mount Installation 12 4 Maintenance 15 4 1 Replacing the Mains Power Supply Fuse 15 4 2 Spare Parts 16 5 Product Specification 17 6 Mechanical Dimension 18 7 Safet...

Page 4: ...RCS01 Product Manual Issue 03 complete approved Page 4 of 24 This page intentionally left blank...

Page 5: ...rge the lithium polymer batteries which are built into the RPA01 transmitters The unit is supplied with two mounting brackets and four rubber feet It can be fixed to a wall or desk with the mounting p...

Page 6: ...The power LED illuminates to indicate that the Charging Station is powered on 2 Lift up one of the charging bay lids and place the RPA01 transmitter into one of the four bays so that the battery cont...

Page 7: ...ber feet supplied 1 x IEC connector for the power supply cable supplied A pozidrive screwdriver No 2 A medium flat bladed screwdriver Installing the Feet Push the four rubber feet supplied into their...

Page 8: ...rminal marked N Earth to terminal marked E or g Re fit the cable grip back into position using the two screws h Secure the cable in the cable grip by tightening the two screws i Re fit the cover using...

Page 9: ...lat bladed screwdriver Suitable fixings for the unit A screwdriver nut spinner or other appropriate tool to fix the above fixings Installing the Fixing Brackets Fit the two fixing brackets to the base...

Page 10: ...four fixing holes on 60 mm x 450 mm centres See Figure 2 for further details VIEW OF CHARGING STATION BASE FIXING HOLES FIXING HOLES 450 mm 60 mm 2 Prepare the mounting holes appropriately 3 Fix the C...

Page 11: ...minal marked N Earth to terminal marked E or g Re fit the cable grip back into position using the two screws h Secure the cable in the cable grip by tightening the two screws i Re fit the cover using...

Page 12: ...edium flat bladed screwdriver Suitable fixings for the unit A screwdriver nut spinner or other appropriate tool to fix the above fixings Installing the Fixing Brackets Fit the two fixing brackets to t...

Page 13: ...four fixing holes on 60 mm x 450 mm centres See Figure 3 for further details 450 mm 60 mm VIEW OF CHARGING STATION REAR FIXING HOLES FIXING HOLES 2 Prepare the mounting holes appropriately 3 Fix the C...

Page 14: ...minal marked N Earth to terminal marked E or g Re fit the cable grip back into position using the two screws h Secure the cable in the cable grip by tightening the two screws i Re fit the cover using...

Page 15: ...wer Supply Fuse Please read and observe the Safety and Precautions section on page 21 of this manual FUSE DRAWER 2 x T 1A L 250V 1 Ensure that the power switch on the Charging Station is switched off...

Page 16: ...aight female connector rewirable K0618003 RCS01 Charging Station Fixing Kit Manufacturer Supplier Application Solutions Safety and Security Ltd Manufacturer Supplier Part No K0618003 Manufacturer Supp...

Page 17: ...Black Environmental Temperature Storage and Operating 5 C to 50 C Humidity Range 0 to 93 Non condensing Safety and EMC EMC EN50121 4 2006 ENV50204 1996 Safety EN60950 2000 Dimensions and Weight Deskt...

Page 18: ...9 mm 414 mm 90 mm 100 mm 78 mm 98 mm BACK VIEW FRONT VIEW 84 mm 90 mm 78 mm 84 mm BOTTOM VIEW THIRD ANGLE PROJECTION 376 mm 78 mm 19 mm 10 mm power RCS01 RPA Transmitter Charging Station STATUS INDICA...

Page 19: ...VIEW FRONT VIEW BOTTOM VIEW 100 mm 80 mm 98 mm 85 mm 450 mm 60 mm 12 mm 9 4 mm power RCS01 RPA Transmitter Charging Station STATUS INDICATOR AMBER CHARGING GREEN CHARGED 85 mm 80 mm 78 mm 78 mm 78 8 m...

Page 20: ...mm 100 mm 98 mm 60 mm 12 mm 9 4 mm BACK VIEW FRONT VIEW BOTTOM VIEW power RCS01 RPA Transmitter Charging Station STATUS INDICATOR AMBER CHARGING GREEN CHARGED 78 mm 85 mm 85 mm 78 mm 78 8 mm 50 mm 60...

Page 21: ...a protective earthing connection Ensure power supply cabling is adequately rated for the unit s operating current and protected in case of short circuit by a correctly rated fuse or circuit breaker Al...

Page 22: ...he following documentation available from the Data Downloads page of Application Solutions Safety and Security Ltd website www asl control co uk Table 1 Reference Documents Ref No Title Filename Ref O...

Page 23: ...ation to the unit or inexpert attempted repair 9 No fault found where no fault can be found after extensive testing indicating user error or failure in ancillary equipment 10 Electronic assemblies whi...

Page 24: ...Application Solutions Safety and Security Ltd www asl control co uk...

Reviews: