Detailed interface data
Signal directions refer to the master clock.
Conn no. Signal
Remark
Description
Signal level
Conn 01
1
Chassis GND RS485
NMEA input
RS485 input. 300-38400 Baud. Connector: 3-
polar screw terminal, max. conductor size
2.5mm2.
Output protocol see separate description
–7V to 12V,
according to RS485
standard.
2
-Rx RS485
3
+Tx RS485
4
Chassis GND RS485
NMEA output
RS485 input. 300-38400 Baud. Connector: 3-
polar screw terminal, max. conductor size
2.5mm2.
Output protocol see separate description
–7V to 12V,
according to RS485
standard.
5
-Rx RS485
6
+Tx RS485
7
Not used
No connection
8
GND
GPS Receiver Connection for the GPS receiver: +24V, 0V, DCF.
Connector: 3-polar screw terminal, max.
conductor size 2.5mm
2
.
24VDC, max. output
current 0,2A.
9
+
10
DCF
11
+24V
24V output
Connector: Screw terminal, max. conductor size
2.5mm
2
.
24VDC, max. output
current 0,5A.
12
0V
Conn 02
Ethernet
RJ45 connector for Ethernet. 10/100BASE-T.
Ethernet version 2/IEEE 802.3
Conn 03
2
Rx RS232
RS232 input
RS-232 in/output. 300-38400 Baud.
DB9 male connector. Rx, Tx, SG.
Output protocol see separate
description
Max. +/- 15VDC,
according to RS232
standard.
3
Tx RS232
RS232 output
5
GND RS232 Signal GND
Conn 04
1, 3
Impulse 1A
Impulse
output no. 1
Impulse output. Connector: Screw terminal, max.
conductor size 2.5mm
2
.
27 V impulses. Max.
load 2A.
2, 4
Impulse 1B
5, 7
Impulse 2A
Impulse
output no. 2
Connector: Screw terminal, max. conductor size
2.5mm
2
.
27 V impulses. Max.
load 2A.
6, 8
Impulse 2B
9, 11
Impulse 3A
Impulse
output no. 3
Impulse output. Connector: Screw terminal, max.
conductor size 2.5mm
2
.
27 V impulses. Max.
load 2A.
10, 12
Impulse 3B
Conn 05
Impulse output configured for 2-wire clocks
1, 4, 7, 10 Impulse 4A
Impulse
output no. 4
Impulse output. Connector: Screw terminal, max.
conductor size 2.5mm
2
.
27 V impulses. Max.
load 2A.
2, 5, 8, 11
Impulse 4B
Conn 05
Impulse output configured for 3-wire clocks
1, 4, 7, 10 Impulse 4A
Impulse
output no. 4
Impulse output. Connector: Screw terminal, max.
conductor size 2.5mm
2
.
27 V impulses. Max.
load 2A.
2, 5, 8, 11
Impulse 4B
Conn 06
1
Common
Alarm relay
output
Common, NC, NO
Connector: 3-polar screw terminal, max.
conductor size 2.5mm
2
.
Max. load:
24VAC/DC 2A
2
NO
3
NC
4
Common
Program relay Common, NC, NO
Max. load:
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Summary of Contents for Marine Master Clock 70000
Page 1: ...MASTERCLOCKSYSTEM TECHNICAL USER MANUAL A100K10807 TECHNICAL MANUAL...
Page 114: ......
Page 116: ......
Page 117: ...www zenitel com ZenitelNorwayAS...